background image

Technical Data

TD6400 | 2 x 4 CH DECODER / ZONE SELECTOR

PAGE 11

Note:

The above specifications are correct at time of printing but subjected to changes without prior notice due to product 

improvements.

Operating voltage 

                                    

Consumption                                                      
Max load / channels 

                                                      

Cascade quantity 
Configuration                                               
Input circuits   
Audio Output                                                                                                 
Number of zones 

                                               

Amplifier inputs                           
Zone selection                                          
Indicators                                                     
Switch mode                                              
                                                                                                                                

AUDIO

Input impedance (Ohm) 

                                  

Output impedance 

                           

Freq response 

                                

Audio input   

                                      

Max audio output 

                                

DATA

Data protocol                                                             
Baud rate   

                                  

Dimension (W x H x D) 

                           

Weight 

 

                                       

24V DC 

6W (250 mA)

500W  at 100V line                                     

                                  

 

         


8                          

Front panel switch & remote 

Individual zone switch

Individual, All Call Local zone selection 

bypassed when remote trigger is actived

Line : 10 K

600 Ohm balanced

70 ~ 15 KHz

Line

Line 1.2V

RS485

19.2 kbps

482 x 44 x 180  mm

2.00 kg  

31 ( 248 zone )

2 in x 4 zones

3 : 1 mic, 2 BGM

2

Summary of Contents for TD6400

Page 1: ...TD6080 but the output zones are divided further to work with 2 x 4 outputs It provides more flexibility when it is to work with Matrix Controller MxP2288 as matrix output zone extender This shall reduce the number of unused zones in matrix groupings DUAL 4 CH DECODER ZONE SELECTOR ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 ALL CALL POWER amperes TD 6400 ...

Page 2: ... of regulated source is used Amperes PS9400 is recommended as a DC supply source to your installation BGM source from mixer output This shall be used when there is audio BGM grouping in the system Front View Rear View DUAL 4 CH DECODER ZONE SELECTOR ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 ALL CALL POWER amperes TD 6400 DC 24V TD 6400 DECODER SELECTOR GROUP A 1 2 3 4 5 7 8 ON 6 ON G...

Page 3: ...or link to BAS system etc Refer to page 10 for connection diagram Outputs from amplifiers are connected to these terminals and speaker zoning is configured to the respective unit of amplifier The user has the flexibility to configure the zoning system as each zone comes with single amplifier output connection Please observe polarity when terminating the amplifier speaker zones and ensure that each...

Page 4: ...MAX MIN MIN CH3 CH1 CH2 SIG IN SIG IN MAX MIN MAX MIN MAX MIN MAX AUX SIG IN a m pe re s MX 2 2 2 2 O I MENU a m pe re s O I POWER QP2500 UP DOWN 500W 100V LINE POWER AMPLIFIER Zone Output MX2222 PREAMPLIFIER MIXER audio output Amp 100V Line O P audio data Zone 1 Zone 8 The illustration using multiple paging mic with TD6400 as zone decoder and zone selector Note All PD Series of Amperes paging mic...

Page 5: ... 2 ON 100V COM COM IN 2 OUT 1 COM COM 100V 100V COM 100V OUT 2 100V IN 1 100V COM OUT 5 COM IN 6 100V 100V IN 5 100V COM 100V OUT 4 COM COM OUT 6 COM OUT 3 100V IN 3 COM 100V COM IN 4 100V COM 100V OUT 8 COM OUT 7 100V IN 7 COM 100V COM IN 8 100V GROUP A GROUP B G MIC IN MIC INPUT G MIC LINK MIXER INPUT BALANCED OUTPUT G GROUP B GROUP A A B RS485 G GROUP B GROUP A UNIT START ADDRESS LINE LEVEL INP...

Page 6: ...NPUT OUTPUT For long distance only Cat5e 24V 2 pair screen cable 18 AWG cable size is recommended PAGE 6 TD6400 2 x 4 CH DECODER ZONE SELECTOR DC 24V TD 6400 DECODER SELECTOR GROUP A 1 2 3 4 5 7 8 ON 6 ON GROUP B 1 2 3 4 5 7 8 ON 6 ON MASTER SLAVE TIME OUT 5 MIN S M 0 5 1 2 ON 100V COM COM IN 2 OUT 1 COM COM 100V 100V COM 100V OUT 2 100V IN 1 100V COM OUT 5 COM IN 6 100V 100V IN 5 100V COM 100V OU...

Page 7: ...C INPUT G MIC LINK MIXER INPUT BALANCED OUTPUT G GROUP B GROUP A A B RS485 G GROUP B GROUP A UNIT START ADDRESS LINE LEVEL INPUTS OUPUTS RELAY CONT 3A NO MAX COM NO NC RELAY TRIG Another Quality Product From AMPERES ELECTRONICS 4 8 1 2 64 128 16 32 4 8 1 2 64 128 16 32 REMOTE PAGING MIC M P 2288 12 x 8 ETHERNET MATRIX CONTROLLER x BALANCED CHANNEL OUTPUTS BALANCED INPUTS XLR MIC LEVEL PHONE JACK L...

Page 8: ... OUT 2 100V IN 1 100V COM OUT 5 COM IN 6 100V 100V IN 5 100V COM 100V OUT 4 COM COM OUT 6 COM OUT 3 100V IN 3 COM 100V COM IN 4 100V COM 100V OUT 8 COM OUT 7 100V IN 7 COM 100V COM IN 8 100V GROUP A GROUP B G MIC IN MIC INPUT G MIC LINK MIXER INPUT BALANCED OUTPUT G GROUP B GROUP A A B RS485 G GROUP B GROUP A UNIT START ADDRESS LINE LEVEL INPUTS OUTPUTS RELAY CONT 3A NO MAX COM NO NC RELAY TRIG An...

Page 9: ...UT 5 MIN S M 0 5 1 2 ON 100V COM COM IN 2 OUT 1 COM COM 100V 100V COM 100V OUT 2 100V IN 1 100V COM OUT 5 COM IN 6 100V 100V IN 5 100V COM 100V OUT 4 COM COM OUT 6 COM OUT 3 100V IN 3 COM 100V COM IN 4 100V COM 100V OUT 8 COM OUT 7 100V IN 7 COM 100V COM IN 8 100V GROUP A GROUP B G MIC IN MIC INPUT G MIC LINK MIXER INPUT BALANCED OUTPUT G GROUP B GROUP A A B RS485 G GROUP B GROUP A UNIT START ADDR...

Page 10: ...TOR GROUP A 1 2 3 4 5 7 8 ON 6 ON GROUP B 1 2 3 4 5 7 8 ON 6 ON MASTER SLAVE TIME OUT 5 MIN S M 0 5 1 2 ON 100V COM COM IN 2 OUT 1 COM COM 100V 100V COM 100V OUT 2 100V IN 1 100V COM OUT 5 COM IN 6 100V 100V IN 5 100V COM 100V OUT 4 COM COM OUT 6 COM OUT 3 100V IN 3 COM 100V COM IN 4 100V COM 100V OUT 8 COM OUT 7 100V IN 7 COM 100V COM IN 8 100V GROUP A GROUP B G MIC IN MIC INPUT G MIC LINK MIXER ...

Page 11: ... of zones Amplifier inputs Zone selection Indicators Switch mode AUDIO Input impedance Ohm Output impedance Freq response Audio input Max audio output DATA Data protocol Baud rate Dimension W x H x D Weight 24V DC 6W 250 mA 500W at 100V line 8 8 Front panel switch remote Individual zone switch Individual All Call Local zone selection bypassed when remote trigger is actived Line 10 K 600 Ohm balanc...

Page 12: ...d out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certificate is valid only for the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the material and manufacturing defects and is valid fo...

Reviews: