Operating The Unit

Technical Data

Select the zone for paging

Select  the  individual  zone  for  paging  or  as  group  or  ALL  CALL, 
LEDs at the switches shall lit accordingly.

Press 

Chime 

+  Talk 

button to page

A 4 tone upward chime shall be broadcasted to the zones selected.

This shall be followed by activation of gooseneck mic, indicated by 
LED  ring  near  the  mic  capsule.  The  console  is  now  ready  for 
paging.

Press Chime + Talk button 
to end

A  4  tone  downward  chime  shall  be  broadcasted  to  the  selected 
zones.

LED ring turned off and the console is deactivated.

PD1240

24V DC via EX2800 with local power adaptor

1.2W

24 zone keys, Group, All Call

Sensor touch keypad

Gooseneck condenser capsule; unidirectional

600 Ohm

Chime, mic volume

RS485; 19.2 kbps

2 pair screen; 22 AWG / Cat 5e decoder

500m subject to cable size

MxP2188, TD6240, TD6080

4 tone up and 4 tone down

Zones, power, audio, data, gooseneck ring LED

NIL

100 - 12 kHz

Appr. 1.6kg

>65 dB @ 1 KHz

230 x 192 x 65 mm (Excluding Mic)

Operating voltage 

                                  

Power Consumption 

        

Zone Selection                                 

Switching selection                                                             

Microphone                                          

Output impedance 

                                                           

Output level                                                 

Output controls  

Data connections                                                              

Cabling to decoder                                                    

Recommended operating distance                                                                                         

Compatible interfacing device                                      

Chime                                                                                        

Indicators                                                    

Displays                                                           

Frequency response                                                                                                                                                                                               

S / N ratio                                                                        

Gooseneck mic length                                                               

Dimension (W x H x D)

Weight  

                           

1.2V balanced line output

400 mm

All Call Paging with 24V Override

Pressing ALL CALL from PD1240 shall activate all the zones at the zone selectors. If any volume controllers are 
installed in the particular zone and is switched off, this feature shall not override the VC. This is to avoid unneces-
sary interruption to the areas concerned, especially Emergency or Privacy Zones, such as Boardroom, Prayer Hall, 
Function Hall, etc.

To override the volume controllers during emergency, use EP1200A installed at the rack. Please refer to ZS manual 
to make necessary connection.

Summary of Contents for PD1240

Page 1: ...ou make the right decision to choose Amperes which is not only offering the product that meets your budget but perform beyond your expectation We appreciate that you read through the manual to avoid a...

Page 2: ...Only condenser microphone supplied or those operates under 3 to 9 V 2 GROUPING SELECTION Each group represents 6 zones This is a convenient way of selecting zones according to groups 3 SIREN BUTTON Pr...

Page 3: ...fed to this port forming a circuit This connection is applicable only if multipoint paging setup is established Use a DC24V power adaptor supplied for powering the unit 6 REPEAT BUTTON Press repeat b...

Page 4: ...n be made freely to the connectors unlike the previous version PD1240 can also be used with MatriMix system In this case EX1102 shall be used instead of EX2800 as the external connection unit PD1240 M...

Page 5: ...in a single circuit In this case loop the data audio cable via the EX2800 terminals accordingly 1 Data A 2 Data B 3 Audio Ve 4 Audio Ve 5 Screen Ground MIC CHIME POWER AUDIO DATA POWER QUANTUM PAGING...

Page 6: ...CHIME AND TALK In setup mode the following parameter can be made Unit priority Priority level from 1 to 6 with 1 being highest Press from to Chime 1 First Chime Press Chime 1 or Chime type 2 Type 1 Ch...

Page 7: ...188 TD6240 TD6080 4 tone up and 4 tone down Zones power audio data gooseneck ring LED NIL 100 12 kHz Appr 1 6kg 65 dB 1 KHz 230 x 192 x 65 mm Excluding Mic Operating voltage Power Consumption Zone Sel...

Page 8: ...the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the material and manufacturing defec...

Reviews: