background image

PAGE 4

amperes electronics

General Schematic Diagram

The above configuration shows a typical system with 24 speaker zones, using 3 units of PD1240 with 
a single TD6240 ( 24 zone decoder ) and 2 ZS5121.

Other made of zone selectors of Amperes ZS5602 can be used to replaced ZS5121.

Priority  setting  is  done  at  each  individual  mic,  connected  to  TD6240  remote  mic  inputs.  Note  that 
connection to the TD6240 can be made freely to the connectors unlike the previous version.

PD1240  can  also  be  used  with  MatriMix  system.  In  this  case  EX1102  shall  be  used  instead  of 
EX2800 as the external connection unit.

PD1240 
Mic Nbr 1

PD1240
Mic Nbr 2

PD1240 
Mic Nbr 3

EX2800

EX2800

EX2800

TD6240 Zone Decoder
(24 channel)

MX2222 Pre-amplifier
Mixer

Power Amplifier

ZS5121 Spk Zone Selector
(Zone 1 to 12)

ZS5121 Spk Zone Selector
(Zone 13 to 24)

Speakers

12V DC
via adaptor

8 core cable ( Cat 5 )

connection via RJ45 Jack

Each cable to cater for 6 

zones

Cat 5e

Cat 5e

Cat 5e

At remote location

2 pair screen cable

12V DC
via adaptor

Summary of Contents for PD1240

Page 1: ...ou make the right decision to choose Amperes which is not only offering the product that meets your budget but perform beyond your expectation We appreciate that you read through the manual to avoid a...

Page 2: ...Only condenser microphone supplied or those operates under 3 to 9 V 2 GROUPING SELECTION Each group represents 6 zones This is a convenient way of selecting zones according to groups 3 SIREN BUTTON Pr...

Page 3: ...fed to this port forming a circuit This connection is applicable only if multipoint paging setup is established Use a DC24V power adaptor supplied for powering the unit 6 REPEAT BUTTON Press repeat b...

Page 4: ...n be made freely to the connectors unlike the previous version PD1240 can also be used with MatriMix system In this case EX1102 shall be used instead of EX2800 as the external connection unit PD1240 M...

Page 5: ...in a single circuit In this case loop the data audio cable via the EX2800 terminals accordingly 1 Data A 2 Data B 3 Audio Ve 4 Audio Ve 5 Screen Ground MIC CHIME POWER AUDIO DATA POWER QUANTUM PAGING...

Page 6: ...CHIME AND TALK In setup mode the following parameter can be made Unit priority Priority level from 1 to 6 with 1 being highest Press from to Chime 1 First Chime Press Chime 1 or Chime type 2 Type 1 Ch...

Page 7: ...188 TD6240 TD6080 4 tone up and 4 tone down Zones power audio data gooseneck ring LED NIL 100 12 kHz Appr 1 6kg 65 dB 1 KHz 230 x 192 x 65 mm Excluding Mic Operating voltage Power Consumption Zone Sel...

Page 8: ...the described product and is not valid if modifications are made on this certificate or on the identification label applied on the product This warranty covers all the material and manufacturing defec...

Reviews: