iEP1202 | ETHERNET EMERGENCY PAGING MICROPHONE
PAGE 3
Parts Identification
11. RESET BUTTON
10. ETHERNET PORT
9. MIC LEVEL CONTROL
This is to adjust the front paging mic volume. It is recommended that the setting is made during testing and commissioning.
Connection to network switch. The unit is non - POE equipment, thereby external 24V DC power supply is required.
7. POWER SWITCH
To turn On / Off iEP1202 power.
8. SIREN LEVEL CONTROL
This is to adjust siren volume. It is recommended that the setting is made during testing and commissioning.
Button to allow iEP1202 enters Bootloader mode or reset settings to factory defaults/
Bootloader mode : To enter this mode, hold the Reset button until Power, Server, Streaming, Siren / Mic and Message LEDs
lit. Only enter this mode for firmware updates when normal updating mode does not work. All iEP1202 settings and
message library files shall remain intact.
Reset to Factory Default settings : Hold the Reset button until Power, Server, Streaming and Siren/Mic LEDs lit. It will reset
all iEP1202 settings to default. All messages in Message Library will be removed.
General Schematic
2
3
4
1
5
6
7
8
1
2
ZONE GROUP KEYS
MESSAGE KEYS
3
4
MIC
POWER
SERVER
STREAMING
SIREN / MIC
SIREN
1202
iEP
NETWORK SWITCH (LAN)
SUB RACK
FCC MAIN RACK
iPD1280
Office
iEP1202
Security Room
iPD1280
Reception
PC with PMX LAN
Operator Room
iPX5101
iPX5200
iEP1200
iPX5155
Other items
as necessary
To Speakers
Cat5e / 6
iPX5155
iEP1200
To Speakers
In iPX setup, the system can be
expanded to multiple sub
systems, working independant-
ly but linked to centralised
paging. Other iP items can
include IP Speakers, IP amplifi-
er terminals, data terminals,
etc.
Multiple units of iEP1202 can be
installed, each with same priority
as iEP1200 and other iEP1202.
ETHERNET
MIC
SIREN
MIN
MAX
MIN
MAX
OFF
ON
POWER
100 mA
DC 24V
Rear View of IEP1202
24V DC Input
to Network Switch