background image

Parts Identification

7

8

9

5

12

10

Front View

1.  AMP STATUS LED & CHANGEOVER

2.  PILOT TONE LED

3.  FAULT ALERT LED AND BUZZER SWITCH

4.  SIGNAL INPUT / OUTPUT TERMINALS 

PAGE 2

AX3800 Auto Amplifier Fault Changeover

5.  SIGNAL LINK SWITCH

Rear View

4

11

AX 3800

amperes

AMP. NORMAL / FAULT

AMP. CHANGEOVER

ON/OFF

AMP FAULT ALERT

PILOT TONE

AMP1

AMP2

AMP3

AMP4

AMP5

AMP6

AMP7

AMP8 AMPSTDBY

STANDBY AMPLIFIER CHANGEOVER

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

CASCADE

INPUT

OUTPUT

AMP. BYPASS

ADD

LINK

OPEN

IN

OUT

IN

OUT

AMP1

AMP2

IN

OUT

IN

OUT

AMP3

AMP4

IN

OUT

IN

OUT

AMP5

AMP6

IN

OUT

IN

OUT

AMP7

AMP8

IN

STDBY

DC 24V

-

+

+IN

GND

-IN

+OUT

GND

-OUT

AMP1

+IN

GND

-IN

+OUT

GND

-OUT

AMP2

+IN

GND

-IN

+OUT

GND

-OUT

AMP3

+IN

GND

-IN

+OUT

GND

-OUT

AMP4

+IN

GND

-IN

+OUT

GND

-OUT

AMP5

+IN

GND

-IN

+OUT

GND

-OUT

AMP6

+IN

GND

-IN

+OUT

GND

-OUT

AMP7

+IN

GND

-IN

+OUT

GND

-OUT

AMP8

+OUT

GND

-OUT

STDBY

A B

1

8

16

8

4

2

1

32 64 128

FAULT

NO

CONTACT

RS 485

LINK

OPEN

LINK

OPEN

LINK

OPEN

LINK

OPEN

LINK

OPEN

LINK

OPEN

BALANCE AUDIO SIGNAL

AMPERES ELECTRONICS

amperes

R

Model : AX3800

MADE IN MALAYSIA

AMP.CHANGEOVER

DC input 24V

Max. 500mA

MKII

amperes electronics

another quality product from

1

2

3

LEDs show status of connected amplifier with :

   AMP. NORMAL / FAULT LEDs :  Green  

- normal operating

   Red 

amplifier 

faulty

   Off 

monitoring 

bypassed

   

   AMP.CHANGEOVER LEDs : 

Green    - faulty and standby amplifier overtake the position of failed duty unit.

Pilot tone indicator which will lit up when 20 kHz pilot tone is sent to all power amplifiers to detect any fault. PT is 

sent in intervals to reduce loading effect which may prolong service life of duty units.

Whenever a fault is detected, it shall be indicated by this LED and a buzzer shall be activated. Use this switch to 

silence the buzzer. LED will still be lit even the buzzer is off and shall turn off after the fault is rectified.

Audio signal from mixer or matrix controller shall be connected to these terminals before being fed to power amplifi-

ers. IN is for incoming while OUT is going to power amplifier input.

6

If more than one channel / amplifiers are sharing the same input signal, slide the switch to LINK. This shall connect 

the input signal to adjacent channel to reduce hardwiring works.

Slide to OPEN if all channels / amplifiers have individual input, such as in Matrix system setup.

The output will still need to be connected to its corresponding amplifier inputs.

6.  STANDBY AMPLIFIER INPUT TERMINAL

This terminal is to connect to standby unit’s audio input. There is no incoming terminal as per other channels.

Summary of Contents for AX3800

Page 1: ...without human intervention to comply with various Codes of Practices such as BS EN or SS By means of pilot tone injection at intervals it ensures power amplifiers are not loaded all the time to preven...

Page 2: ...tus of connected amplifier with AMP NORMAL FAULT LEDs Green normal operating Red amplifier faulty Off monitoring bypassed AMP CHANGEOVER LEDs Green faulty and standby amplifier overtake the position o...

Page 3: ...r item 10 Channel 1 shall have higher priority for standby takeover than subsequent channels This is to ensure that ampli fier serving highest priority shall be connected to channel with lower number...

Page 4: ...2 1 3 5 4 6 ALL CALL PAGING ZONE SELECTION OVERRIDE OVERRIDE AX 3800 amperes AMP NORMAL FAULT AMP CHANGEOVER ON OFF AMP FAULT ALERT PILOT TONE AMP1 AMP2 AMP3 AMP4 AMP5 AMP6 AMP7 AMP8 AMPSTDBY STANDBY...

Page 5: ...dB POWER PROTECT CLIP 480 Watts amperes PA 2480 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 ampe res ampe res O I POWER PUBLIC ADDRESS POWER AMPLIFIER SIGNAL 40 dB SIGNAL...

Page 6: ...ntroller to the inputs of power amplifiers Audio source 1 shall feed to amplifier 1 Link switch 1 shall be switched to OPEN position Audio source 2 shall feed to amplifier 2 5 Link switch 2 3 and 4 sh...

Page 7: ...K OPEN BALANCE AUDIO SIGNAL From Amp Output 1 To Zone Selector From standby amplifier output Channel bypass DIP Switches When connecting amplifier outputs to 100V section at the terminals ensure the p...

Page 8: ...amplifier to serve more than 8 duty units AX3800 will need to be stacked up or cascaded The link between them has been made simpler using RJ45 connectors Unit 1 Unit 2 Unit 3 Cat5e Cat5e To standby a...

Page 9: ...etwork via Amperes iPX5500 Communication Box Application with iPX5500 can be from single or multiple locations When there are several AX3800 connected it is important to set the address correctly with...

Page 10: ...red channel To protect standby amplifier only 1 failed duty amplifier is allowed for changeover at any one time Switch OFF the power amplifier at Ch 8 When PT lits AMP 8 LED will turn red and Changeov...

Page 11: ...asier Channel isolation switch for unused or un monitored channel Individual channel status indicators normal fault and changeover status Technical Specifications Operating voltage Power consumption I...

Page 12: ...med by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the produc...