background image

CPS-A USER MANUAL 

ISPB028 R1 

 

 

Page 6 

 

Overview of Equipment 

3.1

 

Description 

The Ampcontrol CPS-A Intrinsically Safe Compact Power supply forms part of the Gasguard Range of Group I certified Gas 
Detection and Alarm Systems and is also suitable for use with other applications.  

The CPS series of IS power supplies convert 110Vac mains power to intrinsically safe low voltage DC power. 

The DIN rail mount enclosure is made of robust black polycarbonate. Top and bottom enclosure walls have ventilation slots for 
natural convection cooling. The side walls are solid and allow other components to be mounted adjacent to it on the DIN rail. Top 
and bottom ventilation slots must be kept free for air circulation. Screw terminals are located on the front for connecting the AC 
mains cable and the output load circuits. The output has two terminals for each of the positive and negative DC supply. 

WARNING! 

 

The power supply must be mounted in a safe area or in a suitable enclosure with a minimum 
IP 54 rating. 

 

Typical use of this power supply is for voice communication systems, gas detection systems and other electronic equipment 
requiring intrinsically safe power in a Group I application.  

The CPS-A Power supply is an IP 20 plastic enclosure DIN rail mounting Intrinsically Safe power supply designed for Group I 
applications. Several power output versions of the Power Supply are available with a range of voltage and current limits. 

Mounting is by a moulded clip assembly onto a standard TS32 top hat DIN rail.  

Connections are made to enclosed screw clamp type terminals on the front facia of the enclosure. 

3.2

 

Specification 

Supply Voltage:  

110Vac ± 20%, 50/60Hz 

Operating Temperature: 

   0-50

0

C for 12.6V/2.4A 

 

0-60ºC all other models 

Dimensions:  

125 W x 102 H x

 

122 D mm 

Weight:

  

1kg 

Input Parameter:  

Um = 132V 

Output Parameters:   

Refer Table 3.2 (following) 

Table 3.2: 

Output parameters

 

Uo 

Io 

Co 

Lo 

L/R 

12.6V 

2.4A 

10uF 

74uH 

30uH/Ω 

12.6V 

2.4A 

20uF 

40uH 

8uH/Ω 

12.6V 

2.0A 

20uF 

95uH 

40uH/Ω 

15.1V 

1.5A 

1uF 

190uH 

30uH/Ω 

15.1V 

0.469A 

2uF 

450uH 

70uH/Ω 

15.1V 

0.51A 

2uF 

450uH 

65uH/Ω 

 

Summary of Contents for CPS-A

Page 1: ...ured in Australia by Ampcontrol CSM Pty Limited ABN 35 000 770 141 Ampcontrol Electronics Phone 02 4903 4800 Fax 02 4903 4888 No Copies of the information or drawings within this manual shall be made without the prior consent of Ampcontrol Ampcontrol User Manual Part No 142628 ...

Page 2: ...refully read the message that follows and inform other operators CAUTION This safety alert symbol identifies important information to be read in order to ensure the correct sequence of work and to avoid damage or even destruction of the equipment and reduce any potential risk of injury or death to the personnel Supplementary information not directly affecting safety or damage to equipment Carefull...

Page 3: ...se Ampcontrol further reservesthe rightto alter the specification ofthe system and or manual withoutobligation to notifyany person or organisation of these changes Before You Begin We would like to take a moment to thank you for purchasing the Compact Power Supply Ampcontrol CSM Contact details 7 Billbrooke Close Cameron Park NSW 2285 P 61 2 4903 4800 F 61 2 4903 4888 EMAIL electronicsorders ampco...

Page 4: ...ving 4 1 2 Storage after Delivery 4 1 3 Unpacking of Equipment 4 2 General safety 5 2 1 Personnel Safety Warnings 5 2 1 1 Relevant Personnel 5 2 1 2 Safety Communication 5 2 2 Safe Use of Equipment 5 2 2 1 Live Conductors 5 2 2 2 Equipment Knowledge 5 3 Overview of Equipment 6 3 1 Description 6 3 2 Specification 6 4 Installation 7 5 Operation 8 6 Warnings for the Use of the CPS A 10 7 Product List...

Page 5: ...tisnotto be installed immediately proper storage isimportantto ensure protection ofequipmentand validity of warranty All equipment should be stored indoors preferablyon shelves where practicable and protected from the elements Ifstoring on the ground use wooden blocks to elevate the equipment above the ground and ensure thatthe storage area isnotan area where water will collect The storage locatio...

Page 6: ...ell asanySite Safety Rulesor Regulations The responsibilitiesapplicable to those personswho workwith the equipmentmustbe clearlylaid down 2 2 Safe Use of Equipment The equipmentsupplied hasbeen manufactured according to the state ofthe art and designed to ensure a safe operation The equipment may only be used within the design parameters In general the following instructions must be observed in or...

Page 7: ... in a safe area or in a suitable enclosure with a minimum IP 54 rating Typical use of this power supply is for voice communication systems gas detection systems and other electronic equipment requiring intrinsically safe power in a Group I application The CPS A Power supply is an IP 20 plastic enclosure DIN rail mounting IntrinsicallySafe power supplydesigned for Group I applications Several power...

Page 8: ...allic items to penetrate the enclosure during installation of adjacent equipment Ensure adequate space above and below the unit to allow free air movement through the slots WARNING The input mains terminals and output DC terminals have minimum separation distance of 50mm This separation must be maintained by using insulated wires lugs Wiring to the CPS A must comply with local wiring codes and Int...

Page 9: ...videsmaximum available currentup to the Io parameter The power supplyoutputacts as a current limited voltage source The load impedance can vary down to short circuit while the maximum output current is maintained The red overload LED on the facia lights up when operating in current limit The OUTPUT LED is driven directly by the output voltage If the Power Supply is in current limit mode the OUTPUT...

Page 10: ...CPS A USER MANUAL ISPB028 R1 Page 9 ...

Page 11: ...y form of foreign objects into the equipment 4 Do notallow anyalteration to thisproductthatmightviolate the IntrinsicSafetyasthe consequencescould befatal No alteration shall be made without written permission from Ampcontrol Pty Ltd 5 Do not allow the equipment to operate beyond the specification Thiswill compromise the service life resultin premature failure 7 Product List There are five models ...

Page 12: ...t be set to minimum to ensure that the CoC is printed correctly The IECEx CoC On Line System Website is located on the IEC Server which is backed up by the IEC Central Office in accordance with hteir internal procedures in the same manner asthose for the backing up ofall IEC Central Office information including IEC Standards The IECEx Equipment CoC Number assigned to each CoC comprises the followi...

Page 13: ...CPS A USER MANUAL ISPB028 R1 Page 12 ...

Page 14: ...CPS A USER MANUAL ISPB028 R1 Page 13 ...

Page 15: ...CPS A USER MANUAL ISPB028 R1 Page 14 ...

Page 16: ...CPS A USER MANUAL ISPB028 R1 Page 15 ...

Reviews: