Page 13
4.8.1
Battery Connections
A
FireFinder PLUS
requires two (2) 12 volt batteries (TB9). The batteries should be placed into the
bottom right hand side of the cabinet.
A red and black lead coming from TB1 on the Brigade Board will be clearly seen in the same area, this
lead is to be connected to the batteries red to positive and black to negative once the system is
operating on Mains supply.
Battery size is dependent on the system configuration and can vary from 12 AHr to over 100 AHr.
Note:
Refer to Ampac’s battery calculation tool to calculate the required battery size.
TB9 is located on the bottom
right hand side of the board
+27VDC
from PSU
Battery 2
12Volts
Battery 1
12 Volts
+
-
-
+
HPCI
POWER OK
2
2
/0
9
/0
9
SGD
A
U
X
O
U
T
1
A
U
X
O
U
T
2
+
-
N/
C
C
N
/O
N/
C
C
N
/O
1+
1-
2+
2-
3+
3-
4+
4-
2+
3+
4+
C
JTAG
E. BOARD CONTROL
C
O
M
M
S
.
C
O
M
M
S
.
ET
H
BAT+
BAT-
+27V
0 V
COMMS FAIL
E
O
L
1+
E. BOARD SW. POWER
B
R
D
8
6
B
P
SC
4
-
E
X
T
T
E
M
P
L9
R
1
0
3
R
1
0
8
C36
C34
C35
C
5
6
C
5
8
C N4
C N5
C N6
C N7
C
N
1
1
C
N
1
0
CN1
CN2
D9
D10
D11
D7
LK1
M2
M
1
1
M1
M4
M12
M3
M6
M13
M5
M8
M14
M7
M10
M15
M9
Q5
R
7
5
R
L
1
R
L
2
R
L
3
R
L
4
R
L
5
TB1
TB8
TB7
TB2
TB3
TB4
TB5
TB6
T
H
4
T
H
2
T
H
1
T
H
7
T
H
8
U2
U8
U5
U6
U7
ZD8
ZD5
ZD4
ZD1
ZD6
ZD2
ZD7
ZD3
TB
1
0
HSNK2
CN3
N
1
2
3
6
L6
L7
L8
C43
CN12
1
T1
Q8
TH5
HS
NK
1
TH9
C N8
M
1
6
C N 1 0
R S 4 85
C O M MS .
I N
C N 1 1
R S 4 85
C O M MS .
O U T
R
E
L
A
Y
4
R
E
L
A
Y
5
M
O
N
IT
O
R
E
D
O
U
T
P
U
T
S
N/
C
C
N
/O
N/
C
C
N
/O
N/
C
C
N
/O
R
E
L
A
Y
3
R
E
L
A
Y
2
R
E
L
A
Y
1
+
-
POWER
O/Ps
BATT
FLT.
M
O
N
E
N
M
O
N
IT
O
R
E
D
I
N
P
U
T
S
+27VDC
from PSU
Battery 2
12Volts
Battery 1
12 Volts
+
-
-
+
TB9
+
+
-
-
BAT+
BAT-
+27V
0 V
TB9
BRIGADE
BOARD
Figure 9: Battery Connections to the Brigade / PSU Monitor Board
4.8.2
Auxiliary 27 Volt Power
Two (2) 1 Amp outputs are available from TB1 terminals 1+ (plus) and 2- (minus) or 3+ and 4- on the
Brigade Board. It is important to note these outputs are short circuit monitored.
TB1 is located in the lower
left hand side of the board
TB1
+
-
+
-
AUX OUT 1
AUX OUT 2
2 X LIMITED 2A
AUX POWER
OUTPUTS
POWER OK
2
2
/0
9
/0
9
SGD
A
U
X
O
U
T
1
A
U
X
O
U
T
2
+
-
N
/C
C
N
/O
N
/C
C
N
/O
1+
1-
2+
2-
3+
3-
4+
4-
2+
3+
4+
C
JTAG
E. BOARD CONTROL
C
O
M
M
S
.
C
O
M
M
S
.
ET
H
BAT+
BAT-
+27V
0V
COMMS FAIL
E
O
L
1+
E. BOARD SW. POWER
B
R
D
8
6
B
P
S
C
4
-
E
X
T
T
E
M
P
L9
R1
0
3
R1
0
8
C36
C34
C35
C5
6
C5
8
CN4
CN5
CN6
CN7
C
N
11
CN1
0
CN2
D9
D10
D11
D7
LK1
M2
M
11
M1
M4
M12
M3
M6
M13
M5
M8
M14
M7
M10
M15
M9
Q5
R7
5
RL
1
RL
2
RL
3
RL
4
RL
5
T
B
8
T
B
7
T
B
2
T
B
3
T
B
4
T
B
5
T
B
6
T
H
4
T
H
2
T
H
1
T
H
7
T
H
8
U2
U8
U5
U6
U7
ZD8
ZD5
ZD4
ZD1
ZD6
ZD2
ZD7
ZD3
T
B
1
0
HSNK2
CN3
N
1
2
3
6
L6
L7
L8
C43
CN12
1
T1
Q8
TH5
H
S
N
K
1
TH9
CN8
M16
CN10
RS485
COMMS.
IN
CN11
RS485
COMMS.
OUT
R
E
L
A
Y
4
R
E
L
A
Y
5
M
O
N
IT
O
R
E
D
O
U
T
P
U
T
S
N
/C
C
N
/O
N
/C
C
N
/O
N
/C
C
N
/O
R
E
L
A
Y
3
R
E
L
A
Y
2
R
E
L
A
Y
1
+
-
POWER
O/Ps
BATT
FLT.
M
O
N
E
N
M
O
N
IT
O
R
E
D
I
N
P
U
T
S
BRIGADE
BOARD
CN1
T
B
1
+27VDC
from PSU
Battery 2
12Volts
Battery 1
12 Volts
+
-
-
+
HPCI
Figure 10: Auxiliary 27VDC Power Output
Summary of Contents for FireFinder PLUS
Page 1: ...FireFinder PLUS ...
Page 4: ...FIRE BRIGADE RESPONSE GUIDE ...
Page 99: ...Page 92 12 17 3 Panel Interfacing ...
Page 127: ......