Operating Frequency 1500 MHz and Higher (MPE = 10 W/m
2
)
Transmitter Power
Transmitter Power
Transmitter Power
Transmitter Power
0.25 Watts
0.5 Watts
1 Watt
2 Watts
Antenna
Minimum
Minimum
Minimum
Minimum
Gain EIRP Distance EIRP Distance EIRP Distance EIRP Distance
(dBi) (Watts) (Meters) (Watts)
(Meters) (Watts)
(Meters) (Watts) (Meters)
0 0.25 >0.20 0.50 >0.20 1.00 >0.20 2.00 >0.20
2 0.40 >0.20 0.79 >0.20 1.58 >0.20 3.17 >0.20
5 0.79 >0.20 1.58 >0.20 3.16 >0.20 6.32 0.22
10 2.50 >0.20 5.00 >0.20 10.0 0.28 20.0 0.40
15 7.91 0.25 15.8 0.35 31.6 0.50 63.2 0.71
20 25.0 0.45 50.0 0.63 100.0 0.89 200.0 1.26
25 79.1 0.79
158.1
1.12
316.2 1.59 632.5 2.24
30 250.0 1.41 500.0 1.99 1000.0 2.82 2000.0 3.99
Operating Frequency 340 - 400 MHz (MPE = 2.27 W/m
2
)
Transmitter Power
Transmitter Power
Transmitter Power
Transmitter Power
0.25 Watts
0.5 Watts
1 Watt
2 Watts
Antenna
Minimum
Minimum
Minimum
Minimum
Gain EIRP Distance EIRP Distance EIRP Distance EIRP Distance
(dBi) (Watts) (Meters) (Watts)
(Meters) (Watts)
(Meters) (Watts) (Meters)
0 0.25 >0.20 0.50 >0.20 1.00 >0.20 2.00 0.26
2 0.40 >0.20 0.79 >0.20 1.58 0.24 3.17 0.33
5 0.79
>0.20
1.58
0.24 3.16 0.33 6.32 0.47
10 2.50 0.30 5.00 0.42 10.0 0.59 20.0 0.84
15 7.91 0.53 15.8 0.74 31.6 1.05 63.2 1.49
20 25.0 0.94 50.0 1.32 100.0 1.87 200.0 2.65
25 79.1 1.66
158.1
2.35
316.2 3.33 632.5 4.71
30 250.0 2.96 500.0 4.19 1000.0 5.92 2000.0 8.37
MAINTAIN A SAFE PERSONAL DISTANCE FROM THE ANTENNA WHILE
TRANSMITTER IS OPERATIONAL.
FAILURE TO MAINTAIN A SAFE PERSONAL DISTANCE FROM THE
ANTENNA MAY RESULT IN PERSONAL INJURY.
3.0
PREPARATION FOR USE
3.1 Unpacking
Carefully remove the transmitter from the shipping container and make sure all listed
furnished items are included (Section 1.5). Inspect all items for damage. If any item is
omitted from the shipment or appears damaged, contact Dyplex or AMP with detailed
description of problem.