AMP mounting and user manual, Pumps 2022-1
page 7 of 14
Quick guide for use of AMP Pumps 2022-1.
Filter change:
Change - Max 500 hour or 1 year
or pressure difference > 1 bar
Oil service:
Mineral oil SAE 15W-40:
Change every max. 500 hours or 1
year
bad seal rings, condense or cleaning with water can
eventually lead to water in the oil.
Easy access:
Twist the cabinet out to make oil
change and easy service access.
Accumulator control:
1 bar pressure accumulator must be
controlled every max. 500 hours or
once every year.
Control of the V-belt:
Push with 1 kg pressure on center of
V-belt through inspection hole - and
the belt should move from 4 to 6
mm. If more than 6 mm, you need to
tighten.
Control every max. 500 hour or 1
year
Extra V-belt enclosed with pump system purchase.
Electrical fault:
Motor thermal relay will stop power
supply in case of circuit fault.
To restart press the red button
Pressure fault:
Switch of to “0” before restart.
“MAN” position is without any
security functions.
Pressure change:
Adjust with wrench
60 bar +/- 10 bar
Gauges:
All gauges must show values outside
the red areas.
This quick guide is also delivered in a laminated version with the pump.