[email protected] • 813.978.3900
Product Dimensions
–3–
Main low voltage cable
Main low voltage cable shall be sized as one of the following:
A. Underground low energy circuit cable
B. SPT-3 or SPT-2W
C. Any junior hard service cord specified in 24.3.1.2
D. Any other wire rated as sunlight resistant, suitable for wet locations, and
intended for direct burial as defined in the Standard for Thermoplastic-Insulat-
ed Underground Feeder and Branch-Circuit Cables, UL 493.
Fixture low voltage cable
Fixture low voltage cable used to connect the luminaire or fitting to the main
low voltage cable shall be one of the following:
A. Any wire suitable for the main voltage cable, per 53.3.1
B. SPT-1(W)
C. XTW or CXTW, or
D. AWM with equivalent properties.
2.89”
2”
2.83”
1
Separate Built-In Hub Top
Built-In Hub
Top
Stake Mount
Loosen the built-in hub top and
separate the built-in hub top from
the stake mount.