background image

–6–

–6–

[email protected] • 813.978.3900

–7–

Wire Connections

3

Hub Body

By using the Allen wrench, loosen screws and remove the cover from 

the hub body.

Insert the main supply cable, fixture supply cable, other fixture supply 

cable or next hub supply cable into the hub body from the different 

conduit. Strip both ends of all cables. Lift the clamps up and insert the 

ends of neutral wires into the “NEUTRAL” block. Insert the ends of live 

wires into the “HOT” block. Insert the ends of ground wires into the 

“GROUND” block. ensure that each wire is pushed into place securely 

and close the clamps.

Place the cover back onto the hub body and secure with previously 

removed screws. Hand tighten until snug with Allen wrench.

“NEUTRAL” Block

“GROUND” Block

Supply Cable 

from Fixture

“HOT” Block

Supply Cable from 

other Fixture or 

next hub

Screw

Allen Wrench

Cover

Conduit

Adjust Fixture Body Direction

4

Using the Allen wrench, loosen 

the screw on the knuckle and 

adjust the fixture body to your 

desired direction. Once your 

desired direction is achieved, 

tighten the knuckle down with 

the Allen wrench.

ROTATE

Screw

Allen Wrench

Fixture body

Summary of Contents for AFL-40 LI-B-BZ Series

Page 1: ...ALLATION MAINTENANCE GUIDE Help Hotline 1 813 978 3900 Mon Fri 9am 6pm EST www amplighting com AMP Line Voltage Landscape Lighting AMP 120V Brass Flood Light with Knuckle Constant Output AFL 40XX LI B...

Page 2: ...avoid the risk of fire explosion or electric shock this product should be installed inspected and maintained by a qualified electrician only in accor dance with all applicable electrical codes To avo...

Page 3: ...m 813 978 3900 Parts Required 3 Package Contents A 1 Fixture body A 1 Mounting Accessory Sold Separately Products Model Model Input Voltage Hertz Input Cur rent Watt 9W Flood Light 90 277 60 0 2 9 17W...

Page 4: ...20V Brass Flood Light with Knuckle Constant Output AFL 40XX LI B BZ Two installation methods are provided for this fixture Surface Mount Page 5 Stake Mount Page 6 Product Dimensions 2 92 4 47 1 98 3 4...

Page 5: ...e direction after installation Wire Exit Self tapping Screw Supply Cable Mark Place the supply cable in the wire exit Then attach the surface mount with the fixture body to the mounting surface and se...

Page 6: ...d on top of the stake while hammering Note If the ground is hard and the stake is difficult to install make a crosscut in the ground using a flat shovel Board Ground Stake Install Fixture Body to Stak...

Page 7: ...Insert the ends of ground wires into the GROUND block ensure that each wire is pushed into place securely and close the clamps Place the cover back onto the hub body and secure with previously remove...

Page 8: ...tions and product details subject to change without notice Copyright 2021 AMP Lighting Lutz FL USA 33549 All rights reserved customersupport amplighting com 813 978 3900 Help Hotline 1 813 978 3900 Mo...

Reviews: