AML-07-102 (Rev 4)
ezP-1A / ezMEQ5
(PSU/Gain Stage)
Build Date:
Built
By
:
S/N:
Danger - Lethal voltages may exist for
several minutes after power is switched off !
115v
12ax7 / ecc83
12au7 / ecc82
2
3
4
5
6
11
10
9
8
7
10
11
9
8
7
6
5
4
3
2
230v
VTB2
408
VTB2
424
VTB2425
24v
Lamp
VTT2426
Caution - Components can become
VERY HOT during normal operation
Gain Adjust
CUT
OUT
Yellow
Red
Green
Violet
Blue
Grey
Orange
Pink
Blue/Yellow
Brown
White
Brown
Blue
Grey
V
iole
t
Gree
n /
Y
e
llow
Re
d
Re
d
Wh
ite
Wh
ite
23
0
1
2
3
4
5
6
PL1, PL2, PL3 & PL4 = Molex KK Series (4)
PL1 = 12 Way (1)
PL2 = 5 Way (1)
PL3 = 3 Way (1)
PL4 = 2 Way (1)
Latches toward
output transformer
Latch
Latch towards rear
Latch towards rear
24v Lamp Terminals = 0.25in spade terminal (2)
Connectors
J2 = 10 Way Box Header (1) *** Note orientation****
Latch towards rear
***Note orientation***