Troubleshooting Guide

Any problem not resolved by these suggestions may 

require you to contact your local dealer or AMKUS, Inc. for 

further guidance.

Problem

Solution

Engine will not start 

or poor engine 

performance 

Check owner’s manual 

troubleshooting guide.

Rescue tools lack 

power or speed 

Check hydraulic fluid level 

in power unit reservoir.

Fluid leaks at fittings 

or hoses 

Check tightness of hose 

fittings.
Replace damaged hoses.

Parts, Service & Technical Information

Parts, service and technical information can be obtained 

from your local AMKUS dealer or by contacting AMKUS, 

Inc. 1-880-592-6587 or [email protected]

Maintenance Records

It is the responsibility of the user to keep maintenance 

records for each component of the rescue system. 

 

Maintenance shall be performed in accordance with the 

recommendations as outlined in this manual.

Routine Maintenance for Couplings

Couplings should be kept free of dirt and contaminants.  

They may be most easily cleaned by immersing in, or 

scrubbing with, a petroleum based solvent such as SAFE-

SOL

® 

140.  Couplings should then be lubricated with a 

non-water based lubricant such as WD-40

®

.  The rubber 

dust caps which are provided with the tools should also be 

cleaned periodically.  Be aware that while the couplings 

may be clean, the dust caps will accumulate dirt during use.  
Do not cover a clean coupling with a dirty dust cap. 

 

GB2S-XLO Power Unit Specifications

 

Length:  23.0 in. (584 mm)

  Width (with one hose loop standard):  19.0 in. (483 mm)
  Height:  20.5 in. (521 mm)
  Weight (Ready-to-use):  109.6 lbs. (50 kg)

 

(Includes gas, engine oil, hydraulic fluid and couplings)

  Rated Output Pressure:  10,500 psi (724 bar)
  Fluid Type:  AMKUS MV-1 Mineral Base Hydraulic Fluid

 

(For equipment stored and operated in environments below 

     freezing use AMKUS MV-0 Mineral Base Hydraulic Fluid)

  Hydraulic Fluid Reservoir Capacity:  2.0 gals. US (7.6 l.)
  Usable Hydraulic Fluid Capacity:  1.45 gals. US (5.5 l.)
  Maximum Angle of Inclination:  20 degrees from horizontal

General Maintenance and Storage

1. Always store the unit in a clean dry space.
2. Never store tools or power unit hoses under pressure.

After each use:

1. Check to see that important markings are legible.Contact 

your local dealer or AMKUS, Inc. for replacement labels.

2. Wipe hoses, fittings and couplings clean (see routine 

maintenance for hoses and couplings).

3. Inspect the power unit, hoses, fittings and couplings 

after each use for damage, leakage and excessive 

wear.

4. If damage or excessive wear is noticed, do not use the 

power unit; contact your local dealer or AMKUS, Inc. 

Tools do not operate

Check to see that the 

power unit is running
Check to see that the line is 

charged. 

AMKUS RESCUE SYSTEMS

amkus.com

4201 Montdale Drive, Valparaiso, IN 46383-4098 USA

800-592-6587 • 219-548-5000 • Fax 219-476-1669

Summary of Contents for GB2S-XLO

Page 1: ...Designation MTO DECLARED DUAL NUMBER NOISE EMISSION VALUES in accordance with EN ISO 4871 Measured A weighted emission sound pressure level LpA ref 20µPa in decibels 88 2 Uncertainty KpA in decibels 1 5 Measured A weighted sound power level LWA ref 1 pW in decibels 100 2 Uncertainty KWA in decibels 1 5 Values determined according to Annex B of EN 13204 using the basic standards EN ISO 3744 and EN ...

Page 2: ...l and hydraulic fluid levels Add as appropriate Read and understand the engine owner s manual before operating the engine Failure to do so could result in personal injury or equipment damage Set Up Procedures Normally AMKUS equipment is prepared and serviced by your dealer prior to delivery If however you have decided to place the equipment into service yourself please review the following instruc...

Page 3: ... coupling Move the selector valve to charge the line to which the gauge is connected The nominal pressure of the system is 10 500 psi The pressure reading you receive should be between 10 000 psi and 11 000 psi If you have a reading outside of that range contact your local dealer or AMKUS Inc DO NOT ATTEMPT TO ADJUST THE PRESSURE RELIEF SETTING Routine Maintenance for Hoses After each use hoses sh...

Page 4: ... while the couplings may be clean the dust caps will accumulate dirt during use Do not cover a clean coupling with a dirty dust cap GB2S XLO Power Unit Specifications Length 23 0 in 584 mm Width with one hose loop standard 19 0 in 483 mm Height 20 5 in 521 mm Weight Ready to use 109 6 lbs 50 kg Includes gas engine oil hydraulic fluid and couplings Rated Output Pressure 10 500 psi 724 bar Fluid Typ...