Troubleshooting Guide
Any problem not resolved by these suggestions may
require you to contact your local dealer or AMKUS, Inc. for
further guidance.
Problem
Solution
Engine will not start
or poor engine
performance
Check owner’s manual
troubleshooting guide.
Rescue tools lack
power or speed
Check hydraulic fluid level
in power unit reservoir.
Fluid leaks at fittings
or hoses
Check tightness of hose
fittings.
Replace damaged hoses.
Parts, Service & Technical Information
Parts, service and technical information can be obtained
from your local AMKUS dealer or by contacting AMKUS,
Inc. 1-880-592-6587 or [email protected]
Maintenance Records
It is the responsibility of the user to keep maintenance
records for each component of the rescue system.
Maintenance shall be performed in accordance with the
recommendations as outlined in this manual.
Routine Maintenance for Couplings
Couplings should be kept free of dirt and contaminants.
They may be most easily cleaned by immersing in, or
scrubbing with, a petroleum based solvent such as SAFE-
SOL
®
140. Couplings should then be lubricated with a
non-water based lubricant such as WD-40
®
. The rubber
dust caps which are provided with the tools should also be
cleaned periodically. Be aware that while the couplings
may be clean, the dust caps will accumulate dirt during use.
Do not cover a clean coupling with a dirty dust cap.
GB2S-XLO Power Unit Specifications
Length: 23.0 in. (584 mm)
Width (with one hose loop standard): 19.0 in. (483 mm)
Height: 20.5 in. (521 mm)
Weight (Ready-to-use): 109.6 lbs. (50 kg)
(Includes gas, engine oil, hydraulic fluid and couplings)
Rated Output Pressure: 10,500 psi (724 bar)
Fluid Type: AMKUS MV-1 Mineral Base Hydraulic Fluid
(For equipment stored and operated in environments below
freezing use AMKUS MV-0 Mineral Base Hydraulic Fluid)
Hydraulic Fluid Reservoir Capacity: 2.0 gals. US (7.6 l.)
Usable Hydraulic Fluid Capacity: 1.45 gals. US (5.5 l.)
Maximum Angle of Inclination: 20 degrees from horizontal
General Maintenance and Storage
1. Always store the unit in a clean dry space.
2. Never store tools or power unit hoses under pressure.
After each use:
1. Check to see that important markings are legible.Contact
your local dealer or AMKUS, Inc. for replacement labels.
2. Wipe hoses, fittings and couplings clean (see routine
maintenance for hoses and couplings).
3. Inspect the power unit, hoses, fittings and couplings
after each use for damage, leakage and excessive
wear.
4. If damage or excessive wear is noticed, do not use the
power unit; contact your local dealer or AMKUS, Inc.
Tools do not operate
Check to see that the
power unit is running
Check to see that the line is
charged.