WEB INTERFACE
Identification:
This part allows to inform the site and the
particular localization on the site (in case of
a multi-room complex).
These two pieces of information will be
included in the event log and level histories.
Test Measuring chain:
This test will then be done at each startup and randomly. In case of default, a message will be integrated
into the history.
The sensor CAP65 is equipped with a piezo speaker to test the acoustic integrity of the microphone.
This string must be calibrated at the installation
.
Run Process
General Purpose Output 1/ General Purpose Output 2:
The RJ45 output GPO1/GPO2 connector has two low voltage relay outputs to connect different
complementary elements (beacon, alarm), see 5 page 20.
This output allows to connect and supply the figurative displays AMIseries.
These two relays "GPO 1 and GPO2" are programmable at the same time in acoustic level, in weighting
A or C and in Leq 1s, 1min, 5min, 10min, 15min or 60 min.
If the sensor such as CAP40/50 and CAP90 does not have this feature, disable this self test, by turning off
the button
Enable.
This page allows you to configure 3 types of alarms : E-mail Alert 1 ; E-mail Alert 2 ; E-mail Alert 3
On each alarm you can program:
Weighting A /Weighting C :
Weighting A or C.
Repetition in Hour:
Number of alerts in the
hour before sending an e-mail information.
Reference:
The reference Leq is: leq
1s,1min,5min ,10 min,15min and 60 min.
Alert Delay:
The delay time between the
moment or an overshoot is detected and the
time or an alarm is generated.
Threshold:
The trigger threshold of the
alarm in dB.