![AMIX AFF 3 Series User Manual Download Page 56](http://html.mh-extra.com/html/amix/aff-3-series/aff-3-series_user-manual_2933468056.webp)
8
AMIX
AFFseries-3
AFF16-3 AND AFF18-3 FRONT PANEL
D
A
B
C
E
0
Leq10min weighted A or C.
0
Leq 60min weighted A or C.
E -
Weighting A, C indication, chosen for the central display B.
This display may change color depending on the sound levels (see note below)
0
Leq15min weighted A or C.
It also allows the display of error codes.
C
-
This Offset indicator shows whether a measurement correction has been applied based on the
position of the microphone relative to the public area.
0
Leq1s weighted A or C.
Main display configurable in A or C weighting. The displayed average can be selected in the
following list using the web server:
0
Leq5min weighted A or C.
0
Leq1min weighted A or C.
D -
Photoelectric cell associated with automatic brightness adjustment.
Comparison with leq max setpoint
B
-
Central display of 120 x 70 mm
A
-
Predictive trend indicator on nine levels, based on the Leq1min.
Leq1min<-3dB Leq1min<-2dB Leq1min<-1dB
Leq1min>1dB
-1dB<Leq1min<0dB 1dB>Leq1min>OdB
Leq1min>2dB
Leq1min>3dB
Leq1min>4dB
Examples: color change according to the sound level.
,
The colors are congurable according to the two high thresholds.
Blink
The levels are below the first configurable threshold