2.2.  Recommended drawing symbol 

Following 

drawing 

symbol 

is 

recommended 

for 

panel 

computer 

APBDG0L031K0FA

.  

Vcc
PE

2

1

APBDA0L031K0FA

3

GND
SB

4

X11

ETH1

M12

X13

USB

Type A

X1

PWR

X2

AUDIO

D-sub DE-9

 

Fig. 2 -  

APBDG0L031K0FA

 drawing symbol 

 

Summary of Contents for APBDG0L031K0FA

Page 1: ...apbdg0l031k0fa_g_en_101 APBDG0L031K0FA Panel computer for rolling stock Operation manual Version 1 01...

Page 2: ...ll pages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must not be...

Page 3: ...processor modules 20 6 1 Master processor module 20 6 2 Auxiliary processor module 20 7 Communication lines and peripherals 21 7 1 Ethernet 21 7 2 USB 23 7 3 Audio 24 7 4 Piezo buzzer 25 7 4 1 Extern...

Page 4: ...xx_ms_en_xxx pdf 2 Panel computers APBxxx series Service manual file apbxxx_mr_en_xxx pdf 3 APT Flash Loader Flash image manipulation and diagnostic utility for APT APU series of panel computers User...

Page 5: ...AM 4 GB SATA SLC FLASH RTC battery backup TFT LCD 10 4 resolution 1024 768 pixels LED backlight 2 USB with A type USB connector 1 Internal piezo buzzer Front panel glass Corning Gorilla Glass 2 PCT ty...

Page 6: ...time fingertip Unlimited Number of sensing channels 29 horizontally 39 vertically Minimal distance between two points of touch multitouch Min 16 mm Resistance to chemicals See Corning Gorilla Glass 2...

Page 7: ...nt Typically 10 mA max 20 mA Galvanic separation Yes Insulation strength 1000 V AC 1 minute Connection point WAGO 769 634 003 000 Connector counterpart WAGO 769 104 021 000 Wire cross section 0 75 mm2...

Page 8: ...000 hours Luminance drop to 50 IF 80 mA Ta 25 C Equipment is intended to operate up to 1 400 m above the sea level Equipment design meets the requirements of class T3 with temperature lower range exte...

Page 9: ...ns All dimensions are stated in mm WEIGHT 3 86 kg DATE 4 12 2015 MAC X11 00 00 00 00 00 00 HiPot HiPot OK TEST OK MU AUX FW APP 0 00 LDR 0 00 POWER 16 8 V to 45 V DC 1 5 A S N ABCD TYPE APBDG0L031K0FA...

Page 10: ...10 35 2 2 Recommended drawing symbol Following drawing symbol is recommended for panel computer APBDG0L031K0FA Vcc PE 2 1 APBDA0L031K0FA 3 GND SB 4 X11 ETH1 M12 X13 USB Type A X1 PWR X2 AUDIO D sub DE...

Page 11: ...0fa_g_en_101 2 3 Block diagram Master CPU 2 GB RAM 4 GB FLASH Power supplies X1 X13 PWR 2x USB X11 ETH1 Auxiliary CPU Buzzer Temperature sensor USB Touch panel LCD USB X2 AUDIO Codec amplifier HDA Fig...

Page 12: ...ocation of labels see Fig 4 Location of labels on computer cover WEIGHT 3 86 kg DATE 4 12 2015 MAC X11 00 00 00 00 00 00 HiPot HiPot OK TEST OK MU AUX FW APP 0 00 LDR 0 00 POWER 16 8 V to 45 V DC 1 5...

Page 13: ...AC address AUX FW APP x xx LDR x xx Auxiliary processor firmware version POWER 16 8 to 45 V DC 1 5 A Power supply voltage Consumption WEIGHT 3 86 kg Weight TEST OK xx Routine testing result HiPot HiPo...

Page 14: ...0 MHz 20 V m EN 61000 4 3 2006 Electromagnetic compatibility EMC Part 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test 1000 MHz to 2100 MHz 10 V m EN...

Page 15: ...EN 61373 2010 Railway applications Rolling stock equipment Shock and vibration tests Complies EN 60068 2 1 2007 Environmental testing Part 2 1 Tests Test A Cold Complies EN 60068 2 2 2007 Environment...

Page 16: ...B is galvanically separated from internal electronics of the computer When installing it is recommended to connect in single point of switchboard the PE terminal with chassis of equipment where the co...

Page 17: ...minal terminal Vcc must be attached to power supply the unit s power supply is switched ON and the internal piezo buzzer shortly beeps Then follows start of operating system and user application is la...

Page 18: ...ocessor for unit s shut down is activated This shut down takes place after elapsing of 1 minute independently on the immediate state of systemic switch off The time adjusted for shut down by dispatch...

Page 19: ...than ton since computer is started see the figure below Vcc SB HW state ton toff2 t SW state Fig 10 Incorrect shut down Signal SB can be connected directly with device Vcc terminal In this case opera...

Page 20: ...BDG0L031K0FA contains an Auxiliary CPU with CORTEX processor The Auxiliary CPU manages the internal sources of graphical terminal and takes care of reliable start and run of Master CPU The Auxiliary C...

Page 21: ...kup battery 7 1 Ethernet APBDG0L031K0FA computer is equipped with an Ethernet interface with M12 4pin type connector HARTING PushPull M12 system compatible WEIGHT 3 86 kg DATE 4 12 2015 MAC X11 00 00...

Page 22: ...etwork cable while ACT LED indicates transmitting or receiving of data On next figure is presented a front view on Ethernet socket 1 4 3 2 4 1 3 2 Fig 13 Ethernet connector wiring PIN TYPE MEANING 1 T...

Page 23: ...USB type A connectors All USB connectors are located on the rear cover of APBDG0L031K0FA computer WEIGHT 3 86 kg DATE 4 12 2015 MAC X11 00 00 00 00 00 00 HiPot HiPot OK TEST OK MU AUX FW APP 0 00 LDR...

Page 24: ...DR 0 00 POWER 16 8 V to 45 V DC 1 5 A S N ABCD TYPE APBDG0L031K0FA AUDIO Fig 15 Location of audio output connector Connector type D sub DE 9 plug PIN Signal Signal type 1 Right Audio output R 2 Right...

Page 25: ...of term dangerous temperature and description of Auxiliary processor commands see the Related documentation APBxxx series of panel computer Service manual file apbxxx_mr_en_xxx pdf 7 4 1 External pie...

Page 26: ...r touch screen connection the SMT C T16 1188S USB digitizer is used which simultaneously supports 16 independent touches including standard motion gestures depends on used OS 7 6 Backup battery APBDG0...

Page 27: ...eat radiating equipment located nearby does not cause exceeding of these maximum temperatures Because of its considerable weight the graphical terminal must be mounted on sufficiently dimensioned base...

Page 28: ...APBDG0L031K0FA apbdg0l031k0fa_g_en_101 28 35 281 A A 226 Fig 20 Location of mounting holes 3 5 5 A A SCALE 2 1 11 Fig 21 Profile of mounting holes...

Page 29: ...st be connected with local installation earth terminal Minimum cross section of supplying wires must be at least 0 82 mm2 All cabling must be carefully tied by cable ties to avoid the excessive connec...

Page 30: ...ordered SP_MB247720 AMiT code SP_MB247720 Drawing sp_mb247720_d_en_xxx pdf Weight 11 45 g Dimensions 30 30 12 mm Quantity 1 Description Backup battery module datasheet Certificate of product quality a...

Page 31: ...cooler corners and connectors are additionally covered by plastic foil This foil must be removed before turning the device on to enable proper cooling The computer is placed in the card box and is pr...

Page 32: ...must not exceed 10 kg and the load must be distributed to the whole top area of the box Already unpacked device can be stored only under environmental conditions defined in technical parameters The de...

Page 33: ...ange interval Special usage conditions for service interval prolongation Computer mustn t be stored more than 1 year before usage Storage temperature must be between 10 C and 35 C Relative storage hum...

Page 34: ...be done by vacuum cleaner Depending on the dustiness of the environment the cleaning without disassembly can be insufficient In this case the equipment can be cleaned by dry soft brush or vacuum clean...

Page 35: ...be disposed of in common public waste It must be delivered to places specified for that purpose and recycled The equipment contains a lithium battery The battery is a dangerous waste Therefore it must...