PRODUCT OUTLINE:

 

Open doors stand for a considerable amount of energy loss in a building.   
A  correctly  installed  AIR  CURTAIN  can  reduce  the  heat  loss  through  the 
door as much as 90%. Except for the obvious energy savings in money, the 
AIR  CURTAINS  prevents  cold  draught  that  can  cause  absence  due  to 
illness  and  also  allows  shops  to  keep  their  doors  open  in  winter  time, 
which  has  proven  to  attract  more  customers.  AIR  CURTAINS  give  a  true 
meaning to 

the slogan “a warm welcome”. 

CONDITIONS OF USE: 

 

Please DO NOT install the unit under following conditions: 

 
1.  Do not operate in areas with ambient temperature over 50

°

C or below 

-10

°

C. 

2.  In  steamy  areas  or  areas  with  relative  humidity  over  95%  at  room 

temperature. 

3.  In areas containing oily smoke. 
4.  In areas where materials or gases may cause explosion. 
5.  Near corrosive gases. 
6.  In areas where the unit may be sprinkled with water. 

DIAGRAM: 

 
 

 

 

 
 

[ Dimensions : mm ] 

Model

 

L1 

L2 

ARH-8509 

900 

221 

183 

ARH-8512 

1200 

221 

183 

ARH-8515 

1500 

221 

183 

 
INSTALLATION: 

 

1.  Unscrew the mounting plate and take it off. (Fig. 1

Fig. 2) 

2.  Drill  a  hole  following  the  instructions,  then  insert  the  bolt  and  fix  it 

with cement. (Fig. 3) 

3.  Hang the mounting plate and ensure that it is fixed.

 

(Fig. 4) 

4.  Install  the  unit  onto  the  mounting  plate  and  ensure  that  it  is  safely 

fixed. Then tighten the screws.

 

(Fig. 5)       

 
CAUTIONS / INSTALLATION: 

 

During installation, please pay special attention to the following points in 
order to obtain the ultimate efficiency. 

 
1.  Install on solid place to avoid vibrations when machine is running, and 

also  for  safety  reasons.  This  way,  unnecessary  noise  caused  by 
vibration can be prevented. 

2.  AIR CURTAINS are designed for indoor use. 
3.  Choose the most suitable model depending on the height of the room. 

If the unit is fixed too high, the shut-off distance will be affected and the 
efficiency will be reduced. 

4.  The  air  is  drawn  in  from  the  front  of  the  unit  and  is  blown  out 

downwards. 

5.  Several units can be mounted next to each other in case of wide door 

openings. In this case, there must be a space 20-40mm between them. 

6.  During installation, there must be no gap between 

the mounting plate and the wall. 

7.  The distance between the unit and the ceiling must 

be at least 30mm. 

8.  The unit must be installed in horizontal position. 
9.  It is recommended to install the unit at a height of 

at least 2.3m above the ground. 

10. For  safe  operation,  use  the  control  switch  to  connect  the  electricity 

source and the unit wire. If you are not going to use the unit for a long 
time, shut the control switch down. 