42
INSTALLATION
Conversion of the appliance to a different gas type than specified by the manufacturer
on the nameplate or purchasing an appliance that is intended for a different gas type
than provided in the building, is entirely up to the user and installer.
Adjust the valves
To adjust the valves turn the burner knob to "small flame" position and ignite the flame.
- For COPRECI valves, remove the hob and adjust the size of an economic flame with a
screwdriver (Fig. 8).
Fig.
In order to check the flame, heat up the burner on a full flame for about 10 min., and then
turn the burner knob to an small flame position. The flame should not go out or jump on the
nozzle. However, if it does, readjust of the valves.
COPRECI valve with flame failure
cut-off device