12
OPERATION
EN
Using cooktops with control knob ignition (Zp)
l
Press the selected control knob and turn anti-clockwise into Burner ON large flame position.
l
Hold depressed until gas is on fire
l
Release the knob and set the required flame size.
Using cooktops with leak protection (Zt)
protection
spark igniter
Hold the burner’s control knob depressed for approx. 10 seconds in Burner ON large flame position. This way, you
activate the protection device.
Repeat the attempt if the protection has not activated for the first time.
Leak protection will cut off the gas supply if there is no flame for approx. 60 seconds.
At the Zt cooktops, the gas supply to the burners is adjusted with the knobs equipped with the leak
prtection.
What to do if surplus gas leak
occurs
1 – gas network
2 – gas cut off valve
A – valve ON
B – valve OFF
10
11
In any emergency, proceed as follows:
l
turn the burners off
l
set the cut off valve OFF (see fig. 9 B)
l
ventilate the kitchen
l
report the unit for repair at a service department of a licensed and authorised repair shop
l
refrain from using the appliance until it is returned to its operating condition
NOTE
The user can fix some minor malfunctions himself, by following the instructions given in this manual.
The burner does not ignite, and gas is smelled;
l
Close burner control knobs
l
Close the gas mains / supply cut off valve
l
Ventilate the kitchen
l
Take the burner out of the cooktop
l
Clean and blow the slots
l
Insert the burner back in place
l
Resume ignition attempt.
If the burner still fails to go on, report for a licensed repair.