DIAGRAM OF POSSIBLE CONNECTIONS
Warning! Heating elements voltage - 230v
.
Warning! In every type of connection protective
grounding has to be connected to PE termina
l
.
H05VV-
F3G4
H05VV-
F4G2,5
H05VV-
F5G1,5
Recom-
mended
type of
connector
cable
For 400/230 V power supply 3-phase
connection with a neutral lead, 4-5
terminals are shorted together, phase
leads connected to 1,2 & 3 terminals,
neutral lead connected to 4-5, PE (pro
-
tective earth) lead connected to
For 400/230 V power supply 2-phase
connection with a neutral lead, 2-3 and
4-5 terminals are shorted together, PE
(protective earth) lead connected to
For 230 V power supply single pha
-
se connection with a neutral lead,
1-2-3 and 4-5 terminals are shorted
together, PE (protective earth) lead
connected to
1
2
3
1N~
L1=R, L2=S, L3=T; N - neutral lead terminal;
- (PE) lead terminal
2N~
3N~
OPERATION
INSTALLATION
Before first use
●
carefully clean the ceramic plate treating it as a glass surface
● when used for the first time the plate can give off a bit of a smell so switch on the ventilation
system or open the window
●
operate the plate observing the safety instructions