![Amica AGH7100 Installation, Use And Maintenance Manual Download Page 22](http://html.mh-extra.com/html/amica/agh7100/agh7100_installation-use-and-maintenance-manual_2932475022.webp)
22
LPG to Natural Gas Conversion
This hob can be converted from
propane operation at a nominal inlet
pressure of 37mbar or butane operation
at a nominal inlet pressure of 28/30mbar
to natural gas at 20mbar.
This conversion must only be carried out by a competent person (i.e.
a Gas Safe registered fitter).
Total rated gas input :
11.3kW
Mains electrical voltage:
230 – 240Vac, 50Hz
Total rated electrical consumption:
2W
Fitting the hob
Unpacking the hob:
Take care not to lose or mishandle any parts.
THIS HOB HAS SHARP
EDGES, PLEASE WEAR ADEQUATE PERSONAL PROTECTIVE
EQUIPMENT (PPE).
Fitting position of the hob:
This appliance must be,
when installed
, a minimum of 50mm from
any back wall and a minimum of 150mm away from any adjacent
Required:
• 7mm AF nut spinner
• Replacement injectors
• NG identity plate
Burner Size
LPG Injector
Natural Gas Injector
Auxiliary
49
72
Semi-Rapid
67
97
Rapid
86
118
Triple / Wok
100
135