12
1
2
3
3
4
5
230V 1N~
INSTALLATION
Electrical connection
Warning:
This appliance must be earthed.
The appliance must be installed by a com-
petent electrician using a double pole control
unit of 32 ampere minimum capacity with
3mm minimum contact separation at all
poles.
We recommend that the appliance is con-
nected by a qualified electrician who is mem-
ber of the N.C.E.I.C. and who will comply with
the I.E.E. and local regulation.
Access to the main terminal is gained by
opening the terminal block cover at the
rear of the appliance (use a small flat-
bladed screwdriver).
Connection shuld be made with 6mm
2
twin and earth cable.
First strip the wires, then push the cab-
lethrough the cable clamp in the terminal
block cover.
Connect the cable to the terminal block
and tighten the cable clamp screw (see
diagram).
Close the terminal box, ensuring that the
cover is engaged on the locking tabs.
Live
(Red or Brown)
Neutral
(Black or Blue)
Earth
(Green / Yellow
or sleeving)
Cable clamp
2
1
Summary of Contents for 507EE1.30HPFG