amiad EBS-10000 Installation, Operation And Maintenance Instructions Download Page 23

 

 EBS 10000 IL                                                                           910101-000109 / 09.17 

Page 23 of 24 

 

Amiad Limited Warranty  

This certificate a

pplies to Amiad Products purchased by You from Amiad or an Amiad authorized Distributor (“

Distributor

”). This limited 

warranty extends only to the original purchaser, and is not transferable to anyone who subsequently purchases, leases, or otherwise 
obtains the Product from the original purchaser.  

1.

 

Amiad hereby warrants that the Products are and will be free from defects in material and workmanship under normal use and 
service. Amiad warrants that it will correct manufacturing defects in the Products, in accordance with the conditions set out in 
this warranty. 

2.

 

This warranty is enforceable for a period of 12 months after the date Bill of Lading or equivalent (the “

Warranty Period

”). 

 

3.

 

In the event that during the Warranty Period the Distributor discovers a defect in material and/or workmanship in any Product or 

part (the “

Defective Product

”), it shall submit a written complaint to Amiad using Amiad's standard customer complaint form. For 

the  receipt  of  the  customer  complaint  form,  the  submission  of  the  complaint  or  any  questions  please  contact  your  customer 
service representative.  

4.

 

Upon written demand by Amiad the Distributor shall return the Defective Products 

 or a sample thereof 

 to Amiad, at Amiad's 

cost. If the customer ships any such Product, Amiad suggests the customer package it securely and insure it for value, as Amiad 
assumes  no  liability  for  any  loss  or  damage  occurring  during  shipment.  Provided  however  that  in  the  event  Amiad  determines 
that the warranty does not apply to such Product, Distributor shall promptly reimburse Amiad for such cost (including freight and 
customs). Any returned Product or part must be accompanied by the warranty certificate and the purchase invoice. It is clarified 
that the Distributor may not return the Defective Product unless such return was coordinate and approved by Amiad in advance.   

5.

 

Amiad's obligation under this warranty shall be limited to, at its option, the repair or exchange, free of charge, of the Product or 
any  part  which  may  prove  defective  under  normal  use  and  service  during  the  Warranty  Period.  The  provision  of  a  repaired  or 
replacement Product during the Warranty Period will result in an extension of the Warranty Period by an additional period of 12 
months, provided that the total accumulated Warranty Period shall in any event be no more than 18 months from the original Bill 
of Lading.  

6.

 

This warranty is valid on the condition that the Products are installed according to Amiad's instructions as expressed in Amiad's 
instruction manuals and according to the technical limitations as stipulated in Amiad's literature or as stated by a representative 
of Amiad.  

7.

 

This warranty will not apply to damaged or defective Products resulting from or related to:  

(i)

 

Fire, flood, power surges or failures or any other catastrophe/and or unforeseen occurrence, such as but not limited to those 

for which the customers are customarily insured;  

(ii)

 

Fault, abuse or negligence of the customer;  

(iii)

 

Customer's responsibilities, including the failure of the intake water to meet the agreed standards, as set forth in a written 

document, approved by Amiad or improper storage.  

(iv)

 

Improper or unauthorized use of the Product or related parts by the customer, including the customer’s failure to operate the

 

Product in conformity with the recommendations and instructions of Amiad, as set forth in Amiad's manuals and other 
written materials, the operation of the Product other than by a trained and qualified operator, or improper installation of 
the Product by a third party not authorized by Amiad;  

(v)

 

Performance by the customer of maintenance and other services other than by a trained and qualified advanced operator, or 

other  than  in  conformity  with  the  recommendations  and  instructions  of  Amiad,  or  other  than  in  accordance  with 
procedures defined in the literature supplied for Products;  

(vi)

 

Any alteration, modification foreign attachment to or repair of the Products, other than by Amiad or its authorized technical 

representatives.  

8.

 

In  no  event  shall  Amiad  be  liable  to  the  customer  or  any  third  party  for  any  damages,  including  indirect,  special,  exemplary, 
punitive  or  consequential  damages,  or  lost  profits  arising  out  of  or  in  connection  with  this  warranty,  or  arising  out  of  or  in 
connection with the Product's performance or failure to perform, even if it has been advised of the possibility of such damages.  

9.

 

Amiad  will  be  excused  for  failure  to  perform  or  for  delay  in  performance  hereunder  if  such  failure  or  delay  is  due  to  causes 
beyond its reasonable control or force majeure preventing or hindering performance. 

10.

 

The limited warranty set forth herein is the only warranty given by Amiad and is provided in lieu of any other warranties created 
by any documentation, packaging or otherwise.  

11.

 

Amiad  makes  no  warranty  whatsoever  in  respect  of  accessories  or  parts  not  supplied  by  Amiad.  In  the  event  that  Amiad  is 
required to correct a defective Product or product not covered by this warranty, it will do so solely in consideration for additional 
fees.

Summary of Contents for EBS-10000

Page 1: ...01 000109 09 17 Page 1 of 24 AMIAD WATER SYSTEMS EBS 10 000 IN LINE FILTER Serial number Order number Catalogue number Filtration degree Tested by Installation Operation and Maintenance Instructions 910101 000109 09 17 ...

Page 2: ... content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes that all u...

Page 3: ... 8 Description and filter operation 9 Installation 10 Commissioning Start up and First Operation 11 Maintenance 12 Troubleshooting 14 Disassembling and reassembling 15 Parts schedule 18 Parts drawing Section 1 20 Parts drawing Section 2 21 Parts drawing Section 3 22 Limited Warranty 23 With any inquiry please quote Filter Serial Number located on the filter housing ...

Page 4: ... Flush data Exhaust valve 80mm 3 Flushing cycle time 30 40 seconds 30 40 seconds Wasted water per cycle 500liter 132USgal at 2bar 30psi Minimum flow for flushing 50m h 220USgpm at 2bar 30psi Control and electricity Electric motor 1 2 HP 50 60 Hz 18 22 Gear output R P M Rated operation voltage 3 phase 220 380 440 V 50 60 Hz Single phase 110 220 V 50 60 Hz Control voltage 24V AC Current consumption ...

Page 5: ...ting at the area of the filter to enable good visibility and safe maintenance The user should arrange suitable platforms ladders and safety barriers to enable easy and safe access to the filter without climbing on pipes and other equipment The user should verify that any platform barrier ladder or other such equipment is built installed and used in accordance with the relevant local authorized sta...

Page 6: ... note that the maximum working pressure indicated at the filter s specifications table includes the pressure caused by fluid hammer and pressure surge effects Civil Engineering Make sure that the filter installation is done by Amiad qualified technicians Make sure that any civil engineering work at the installation site such as construction lifting welding etc is done by qualified workers technici...

Page 7: ...ze slippage electrification or damage to the equipment caused by moisture While using lifting equipment make sure that the filter or the lifted part is chained securely and in a safe manner Do not leave lifted equipment if there is no necessity Avoid working below lifted equipment Wear a safety helmet goggles gloves and any other personal safety equipment required by the local standards and regula...

Page 8: ...EBS 10000 IL 910101 000109 09 17 Page 8 of 24 DIMENSIONAL DRAWING ...

Page 9: ...e timer in the control board to CONT position 4 Malfunction mode During malfunction mode the self cleaning operation is stopped the malfunction light on the control board is turned on and an external output is activated with 24V AC The filtration system may enter a malfunction mode in the following cases 1st When there is a continuous signal from the pressure differential switch for duration of mo...

Page 10: ...remove large objects that may damage the filter s internal mechanism 7 Install a drainage pipe to the exhaust valve Minimum 3 diameter for a maximum pipe length of 20 meters 60 feet for longer drainage 4 pipe diameter must be used for a maximum length of 40 meters 120 feet Please note that no restriction is allowed on the drainage pipe For special applications please consult the manufacturer 8 If ...

Page 11: ...ntrol 24V circuit breakers and the motor protector to ON The motor will start operating The suction scanner shaft should turn clockwise and move downward to the filter housing until it reaches the lower limit switch If the motor rotates in the opposite direction disconnect the electricity immediately and change the direction of the motor rotation by changing between two phases The motor must stop ...

Page 12: ...e filter carefully and safely to its water air and power supply 7 Perform a General Inspection of the Filter Operation as described above Changing the sealing flange internal O ring 1 Close the inlet valve to the filter and release any residual pressure 2 Disconnect and lock the filter s power supply 3 Disconnect and lock the filter s compressed air supply and release any residual pressure 4 Verif...

Page 13: ...ter housing or accessories h Unusual vibrations i Non smooth operation of the filter valves air release valves and check valves 2 Close the inlet and the outlet valves of the filter Drain the filter housing and release any residual pressure 3 Disconnect and lock the filter s power supply 4 Disconnect and lock the filter s compressed air supply and release any residual pressure 5 Disassemble the fi...

Page 14: ...if found faulty The motor protector was activated The fault indication lamp is blinking in red This fault means that the motor was operated under too high load Note All the following checks and actions should be done by a qualified electrician only A Check the motor power consumption when not loaded B Check the limit switches for correct operation and verify that each one of them stop the motor at...

Page 15: ...58 then pull out the connecting pin If the connecting pin is not facing one of the shaft housing windows turn the drive shaft 56 a little Use 17mm or 11 16 spanners 7 Turn the drive shaft 56 counter clockwise so that it will be separated from the suction scanner shaft 12 8 Unscrew bolts 61 and remove the limit switches sling without disconnecting and changing the limit switches position 9 Unscrew ...

Page 16: ...uld be lifted only with Amiad s standard Extractor and a standard lifting device operated by an authorized operator 1 Clean and dry the rubber pads on the Extractor 2 Fold the Extractor upwards Figure 1 Figure 1 3 Insert the Extractor into the screen about a quarter from top Make sure that the extractor cushions do not touch the stitch found along the screen interior 4 Pull the extractor up so tha...

Page 17: ...with two bolts 22 in opposite positions 6 Screw the rest of the housing bolts 22 Tightening opposite positioned bolts will achieve proper sealing 7 Locate the O ring 23 in its groove under the shaft housing 24 Place the bolts 25 but do not yet tighten them firmly 8 Turn the drive shaft 56 clockwise until it reaches the suction scanner shaft Insert the connecting pin 58 into the hole in the drive s...

Page 18: ... NBR N F 1 24 710105 001473 DR SHAFT HOUS EBS 10K EPOXY PKPK 3002 1 25 760101 000328 HEX BOLT PARTIAL THR M16X60 Z PLT C ST 8 26 760103 000069 FLAT WASHER M16 DIN125 ZINC PLATED C ST 16 27 760102 000067 HEX NUT M16 ZINC PLATED C ST DIN934 8 28 710105 001474 DR SHAFT HOUS COVER EBS EPOXY PKPK 3002 1 29 720202 000018 GEAR RMI70 FL 1 70 71 B5 1 30 760101 000314 HEX BOLT FULL THRD M10X40 Z PLT C ST 4 ...

Page 19: ...X16 S ST304 DIN916 2 74 760101 000527 SOCKET SET SCREW M10X50 S ST316 DIN916 2 75 760103 000097 FLAT WASHER M10 DIN125 S ST316 2 76 760102 000087 HEX NUT M10 S ST316 DIN934 2 77 700190 002336 MANOMETER VALVE 1 4 W DRAIN 1 78 720501 000214 T CONNECTOR1 4 FX1 4 FX1 4 M NICKEL PLA 2 79 720501 000202 L CONNECTOR 5 16 X1 4 69F BRASS 2 80 730104 000202 VALVE 3 WAY 1 4 SAGIV SY3 1Y3NO4OA4 1 81 720501 000...

Page 20: ...EBS 10000 IL 910101 000109 09 17 Page 20 of 24 PARTS DRAWING Section 1 ...

Page 21: ...EBS 10000 IL 910101 000109 09 17 Page 21 of 24 PARTS DRAWING Section 2 ...

Page 22: ...EBS 10000 IL 910101 000109 09 17 Page 22 of 24 PARTS DRAWING Section 3 ...

Page 23: ... This warranty is valid on the condition that the Products are installed according to Amiad s instructions as expressed in Amiad s instruction manuals and according to the technical limitations as stipulated in Amiad s literature or as stated by a representative of Amiad 7 This warranty will not apply to damaged or defective Products resulting from or related to i Fire flood power surges or failur...

Page 24: ...233500 Israel Tel 972 4690 9500 Fax 972 48141159 Email info amiad com Obelis s a Bd Général Wahis 53 1030 Brussels Belgium Tel 32 2732 5954 Fax 32 27326003 Email mail obelis net EC Declaration http amiad com pdf certificates MACHINERY_SAFETY pdf ...

Reviews: