amiad EBS-10000 Installation, Operation And Maintenance Instructions Download Page 19

 

 EBS 10000 IL                                                                           910101-000109 / 09.17 

Page 19 of 24 

No. 

CAT. No. 

DESCRIPTION 

Qty. 

52 

710103-002539 

DRIVE BUSHING EBS 

53 

760101-000447 

HEX BOLT FULL TH M6X35 S/ST304 DIN933 

54 

760103-000094 

FLAT WASHER M6 DIN125 S/ST316 

55 

760102-000101 

NYLON INSERT LOCK NUT M6 S/ST304 DIN985 

56 

710103-002540 

DRIVE SHAFT EBSS/ST303 

57 

710103-002541 

DRIVE SHAFT KEY EBS BRASS 8X8 

58 

710103-002542 

CONNECTING PIN EBS 

59 

760105-000038 

SPLIT PIN 2X20 DIN 94 S/ST316 

60 

710103-002558 

LIMIT SWITCH SLING EBS POLISHED 

61 

760101-000444 

HEX BOLT FULL TH M6X20 S/ST304 DIN933 

62 

760103-000094 

FLAT WASHER M6 DIN125 S/ST316 

63 

760103-000109 

SPRING WASHER M6 DIN127 S/ST316 

64 

760102-000085 

HEX NUT M6 S/ST316 DIN934 

65 

720302-000004 

LIMIT SWITCH NC (EBS,SAF)  

66 

760101-000511 

PHILLIPS PAN MACHINE SCREW M4X20 304 

67 

760103-000092 

FLAT WASHER M4 DIN125 S/ST304 

68 

760102-000099 

NYLON INSERT LOCK NUT M4 S/ST304 DIN985 

69 

770101-000055 

O-RING SEAL38X4 SEALING FLANGE EBS NBR S 

70 

710103-002612 

SEALING ROPE FLANGE EBS AND HD 

71 

770101-000053 

O-RING SEAL 30X4SEALING FLANGE EBS NBR S 

72 

710103-002537 

LIMIT SWITCH PLATE EBS 

73 

760101-000516 

SOCKET SET SCREW M4X16 S/ST304 DIN916 

74 

760101-000527 

SOCKET SET SCREW M10X50 S/ST316 DIN916 

75 

760103-000097 

FLAT WASHER M10 DIN125 S/ST316 

76 

760102-000087 

HEX NUT M10 S/ST316 DIN934 

77 

700190-002336 

MANOMETER VALVE 1/4" W/ DRAIN 

78 

720501-000214 

T-CONNECTOR1/4"FX1/4"FX1/4"M NICKEL PLA. 

79 

720501-000202 

L-CONNECTOR 5/16"X1/4" 69F BRASS 

80 

730104-000202 

VALVE 3-WAY 1/4" (SAGIV SY3 1Y3NO4OA4) 

81 

720501-000204 

L-CONNECTOR 5/16"X1/8" 69F NICKEL PLATED 

82 

720301-000044 

PRES.GAUGE 1/4"0-16BAR W/PSI,BOTTOM INLT 

83 

710103-002659 

BRACKET PLATE FOR CAST-IRON EBS 

84 

760101-000443 

HEX BOLT FULL TH M6X15 S/ST304 DIN933 

85 

760103-000109 

SPRING WASHER M6 DIN127 S/ST316 

86 

760103-000094 

FLAT WASHER M6 DIN125 S/ST316 

87 

900103-000020 

NAMEPLATE ALUMINIUM FOR EBS+SAF CE EN 

88 

760105-000036 

RIVET BLIND 3X6 DIN 7337 S/ST316 

89 

700190-002568 

ELECTRICAL JUNCTION BOX EBS 

90 

700190-002618 

PRESSOSTAT SUB-AS. MIDWEST W/O FITTING 

91 

720501-000204 

L-CONNECTOR 5/16"X1/8" 69F NICKEL PLATED 

92 

720501-000210 

PLUG 1/4"M NICKEL PLATED 

93 

770102-000172 

O-RING SEAL P2-443 (6" SERVICE LID)NBR 

94 

740102-000319 

SERVICE LID 6" BSTD, RED, 5555, EBS 10K 

95 

760101-000329 

HEX BOLT PARTIAL THR M16X65 Z.PLT C/ST 

96 

760103-000069 

FLAT WASHER M16 DIN125 ZINC PLATED C/ST 

16 

97 

760102-000067 

HEX NUT M16 ZINC PLATED C/ST DIN934 

98 

730104-000236 

1" BALL VALVE M/F BSP BRASS/NI 

Summary of Contents for EBS-10000

Page 1: ...01 000109 09 17 Page 1 of 24 AMIAD WATER SYSTEMS EBS 10 000 IN LINE FILTER Serial number Order number Catalogue number Filtration degree Tested by Installation Operation and Maintenance Instructions 910101 000109 09 17 ...

Page 2: ... content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes that all u...

Page 3: ... 8 Description and filter operation 9 Installation 10 Commissioning Start up and First Operation 11 Maintenance 12 Troubleshooting 14 Disassembling and reassembling 15 Parts schedule 18 Parts drawing Section 1 20 Parts drawing Section 2 21 Parts drawing Section 3 22 Limited Warranty 23 With any inquiry please quote Filter Serial Number located on the filter housing ...

Page 4: ... Flush data Exhaust valve 80mm 3 Flushing cycle time 30 40 seconds 30 40 seconds Wasted water per cycle 500liter 132USgal at 2bar 30psi Minimum flow for flushing 50m h 220USgpm at 2bar 30psi Control and electricity Electric motor 1 2 HP 50 60 Hz 18 22 Gear output R P M Rated operation voltage 3 phase 220 380 440 V 50 60 Hz Single phase 110 220 V 50 60 Hz Control voltage 24V AC Current consumption ...

Page 5: ...ting at the area of the filter to enable good visibility and safe maintenance The user should arrange suitable platforms ladders and safety barriers to enable easy and safe access to the filter without climbing on pipes and other equipment The user should verify that any platform barrier ladder or other such equipment is built installed and used in accordance with the relevant local authorized sta...

Page 6: ... note that the maximum working pressure indicated at the filter s specifications table includes the pressure caused by fluid hammer and pressure surge effects Civil Engineering Make sure that the filter installation is done by Amiad qualified technicians Make sure that any civil engineering work at the installation site such as construction lifting welding etc is done by qualified workers technici...

Page 7: ...ze slippage electrification or damage to the equipment caused by moisture While using lifting equipment make sure that the filter or the lifted part is chained securely and in a safe manner Do not leave lifted equipment if there is no necessity Avoid working below lifted equipment Wear a safety helmet goggles gloves and any other personal safety equipment required by the local standards and regula...

Page 8: ...EBS 10000 IL 910101 000109 09 17 Page 8 of 24 DIMENSIONAL DRAWING ...

Page 9: ...e timer in the control board to CONT position 4 Malfunction mode During malfunction mode the self cleaning operation is stopped the malfunction light on the control board is turned on and an external output is activated with 24V AC The filtration system may enter a malfunction mode in the following cases 1st When there is a continuous signal from the pressure differential switch for duration of mo...

Page 10: ...remove large objects that may damage the filter s internal mechanism 7 Install a drainage pipe to the exhaust valve Minimum 3 diameter for a maximum pipe length of 20 meters 60 feet for longer drainage 4 pipe diameter must be used for a maximum length of 40 meters 120 feet Please note that no restriction is allowed on the drainage pipe For special applications please consult the manufacturer 8 If ...

Page 11: ...ntrol 24V circuit breakers and the motor protector to ON The motor will start operating The suction scanner shaft should turn clockwise and move downward to the filter housing until it reaches the lower limit switch If the motor rotates in the opposite direction disconnect the electricity immediately and change the direction of the motor rotation by changing between two phases The motor must stop ...

Page 12: ...e filter carefully and safely to its water air and power supply 7 Perform a General Inspection of the Filter Operation as described above Changing the sealing flange internal O ring 1 Close the inlet valve to the filter and release any residual pressure 2 Disconnect and lock the filter s power supply 3 Disconnect and lock the filter s compressed air supply and release any residual pressure 4 Verif...

Page 13: ...ter housing or accessories h Unusual vibrations i Non smooth operation of the filter valves air release valves and check valves 2 Close the inlet and the outlet valves of the filter Drain the filter housing and release any residual pressure 3 Disconnect and lock the filter s power supply 4 Disconnect and lock the filter s compressed air supply and release any residual pressure 5 Disassemble the fi...

Page 14: ...if found faulty The motor protector was activated The fault indication lamp is blinking in red This fault means that the motor was operated under too high load Note All the following checks and actions should be done by a qualified electrician only A Check the motor power consumption when not loaded B Check the limit switches for correct operation and verify that each one of them stop the motor at...

Page 15: ...58 then pull out the connecting pin If the connecting pin is not facing one of the shaft housing windows turn the drive shaft 56 a little Use 17mm or 11 16 spanners 7 Turn the drive shaft 56 counter clockwise so that it will be separated from the suction scanner shaft 12 8 Unscrew bolts 61 and remove the limit switches sling without disconnecting and changing the limit switches position 9 Unscrew ...

Page 16: ...uld be lifted only with Amiad s standard Extractor and a standard lifting device operated by an authorized operator 1 Clean and dry the rubber pads on the Extractor 2 Fold the Extractor upwards Figure 1 Figure 1 3 Insert the Extractor into the screen about a quarter from top Make sure that the extractor cushions do not touch the stitch found along the screen interior 4 Pull the extractor up so tha...

Page 17: ...with two bolts 22 in opposite positions 6 Screw the rest of the housing bolts 22 Tightening opposite positioned bolts will achieve proper sealing 7 Locate the O ring 23 in its groove under the shaft housing 24 Place the bolts 25 but do not yet tighten them firmly 8 Turn the drive shaft 56 clockwise until it reaches the suction scanner shaft Insert the connecting pin 58 into the hole in the drive s...

Page 18: ... NBR N F 1 24 710105 001473 DR SHAFT HOUS EBS 10K EPOXY PKPK 3002 1 25 760101 000328 HEX BOLT PARTIAL THR M16X60 Z PLT C ST 8 26 760103 000069 FLAT WASHER M16 DIN125 ZINC PLATED C ST 16 27 760102 000067 HEX NUT M16 ZINC PLATED C ST DIN934 8 28 710105 001474 DR SHAFT HOUS COVER EBS EPOXY PKPK 3002 1 29 720202 000018 GEAR RMI70 FL 1 70 71 B5 1 30 760101 000314 HEX BOLT FULL THRD M10X40 Z PLT C ST 4 ...

Page 19: ...X16 S ST304 DIN916 2 74 760101 000527 SOCKET SET SCREW M10X50 S ST316 DIN916 2 75 760103 000097 FLAT WASHER M10 DIN125 S ST316 2 76 760102 000087 HEX NUT M10 S ST316 DIN934 2 77 700190 002336 MANOMETER VALVE 1 4 W DRAIN 1 78 720501 000214 T CONNECTOR1 4 FX1 4 FX1 4 M NICKEL PLA 2 79 720501 000202 L CONNECTOR 5 16 X1 4 69F BRASS 2 80 730104 000202 VALVE 3 WAY 1 4 SAGIV SY3 1Y3NO4OA4 1 81 720501 000...

Page 20: ...EBS 10000 IL 910101 000109 09 17 Page 20 of 24 PARTS DRAWING Section 1 ...

Page 21: ...EBS 10000 IL 910101 000109 09 17 Page 21 of 24 PARTS DRAWING Section 2 ...

Page 22: ...EBS 10000 IL 910101 000109 09 17 Page 22 of 24 PARTS DRAWING Section 3 ...

Page 23: ... This warranty is valid on the condition that the Products are installed according to Amiad s instructions as expressed in Amiad s instruction manuals and according to the technical limitations as stipulated in Amiad s literature or as stated by a representative of Amiad 7 This warranty will not apply to damaged or defective Products resulting from or related to i Fire flood power surges or failur...

Page 24: ...233500 Israel Tel 972 4690 9500 Fax 972 48141159 Email info amiad com Obelis s a Bd Général Wahis 53 1030 Brussels Belgium Tel 32 2732 5954 Fax 32 27326003 Email mail obelis net EC Declaration http amiad com pdf certificates MACHINERY_SAFETY pdf ...

Reviews: