Recalling Memory

Time Adjustment

1. Press and hold the “

” button for more

than 3 seconds to enter Time Adjustment
Mode. The display will show a blinking
year.

2. Press the “ ” or “ ” to change the year.
3. Press the “

” button again to confirm the

entry.

4. The display will then show a blinking

Month, followed by the Date, the Hour
and the Minutes. Repeat steps 2 and 3 to
adjust them.

5. A “0” will reappear as

the blood pressure
monitor is ready for
measurement again.

+

Hold for

more than

3 seconds

1. To recall stored blood pressure readings

from memory, simply press the Recall key.
The last set of memorized readings will be
displayed.

2. Another press of the Recall key will recall

the previous set of readings.

Note: The data will be erased when any of the
batteries are removed for at least 10 seconds

mmHg

re

c

a

ll

rap

pel

a

d

d

ajo

ut

Summary of Contents for Physio Logic

Page 1: ...Automatic Wrist Blood Pressure Monitor TM ys Instruction Manual Features Step Valve Technology Memory for up to 30 readings One Touch Operation Easy to read Display Time and Date Display 106 960 ...

Page 2: ...ation 4 Before taking a measurement 5 Installing batteries 7 Recalling memory 8 Time adjustment 8 Statement of accuracy 3 Name function of each part 6 Carrying case 6 Display explanation 7 Applying the arm cuff 9 Correct measuring posture 9 Taking a measurement 10 Troubleshooting 11 Cautionary notes 11 Specifications 12 2 ...

Page 3: ...s air from the cuff Releasing pressure in steps allows the monitor to analyse oscillations in the cuff and evaluate them for accuracy During the deflation the device will detect the amplitude and slope of the pressure oscillations and determine the systolic diastolic andpulseforyou Blood pressure measurements determined with Physio Logic are equivalent to those obtained by a trained observer using...

Page 4: ...intatwhichyouwillbeconsideredatrisk Optimal 120 and 80 Normal 130 and 85 High normal 130 139 or 85 89 Hypertension Stage 1 140 159 or 90 99 Hypertension Stage 2 160 179 or 100 109 Hypertension Stage 3 180 or 110 Category Systolic mm Hg Diastolic mm Hg Blood Pressure for Adults Age 1 8 and Older Blood Pressure Fluctuation Blood pressure fluctuates all the time You should not be overly worried if yo...

Page 5: ...es at different times of the day this will make it easier for you to compare your daily blood pressure readings Agood time to take yourbloodpressureisinthemorning beforebreakfast Don t smoke eat or exercise for 30 minutes before taking your bloodpressure Theseactivitiescanchangeyourbloodpressure Do not measure your blood pressure immediately after consuming a large meal To obtain more accurate rea...

Page 6: ...rt Carrying Case Recall key Battery cover LCD display Wrist cuff Add to memory key Start key Power key 2 AAA size 1 5 V Alkaline batteries Please store your blood pressure monitor in the carrying case as shown below Time set key ...

Page 7: ...ears ondisplay 2 Nothing appears in the display when the power is switched on mmHg Systolic pressure Memory mark Month Date Hour Minute Diastolic pressure Pumping mark Pulse rate Weak battery mark Appears when a measurement value is stored in memory or is recalled from memory Appears while inflating Appears when batteries should be replaced Occurs when a error was made during measurement Shows the...

Page 8: ... Date the Hour and the Minutes Repeat steps 2 and 3 to adjustthem 5 A 0 willreappearas thebloodpressure monitorisreadyfor measurementagain Hold for more than 3 seconds 1 To recall stored blood pressure readings from memory simply press the Recall key The last set of memorized readings will be displayed 2 Another press of the Recall key will recall theprevioussetofreadings Note The data will be era...

Page 9: ...wrist so there is no extra space between the cuff and the wrist as in Figure C If the cuff is not wrapped snugly enough snug not tight the measurementwillbefalse 5 If your physician has diagnosed you with poor circulation in your left arm carefully place the cuff around your rightwristasshown inFig D 1 Place your elbow on a table so that the cuffisatthesamelevelasyourheart 2 If the cuff is not at ...

Page 10: ...tor automatically switches off approximately 3 minutes after last key operation To interrupt the measurement simply press any key The cuff will deflate immediatelyafteranykeyispressed During the measurement do not talk or moveyourarmorhandmuscles systolic diastolic and pulse will show simultaneouslyontheLCDscreen Note The monitor will re inflate automatically to approximately 220 mmHg if the syste...

Page 11: ...lease call our consumer information line at 1 800 363 2381 Under no circumstance should youdisassembletheunitandattemptrepairs EE 11 Cautionary Notes 1 Avoid extreme temperatures humidity and direct sunlight Avoidstronglyshockingthemainunit andprotectitfromdust 2 Clean the blood pressure monitor body and the cuff carefully with a slightly damp soft cloth Do not press Do not wash the cufforusechemi...

Page 12: ...ature Operation humidity 40 to 85 HR maximum Storage temperature Storage humidity 10 to 95 HR maximum Power source 3V DC two LR03 1 5 V AAA batteries Dimensions 81 L x 78 L x 78 H mm Weight 115 g G W without batteries Wrist circumference 13 5 to 19 5 cm 5 3 to 7 7 Minimum age Over 18 years old 10 C to 40 C 50 F to 104 F 5 C to 60 C 23 F to 140 F Specifications are subject to change without notice ...