Optical Connections Singlemode

No. of Optical Connections ..................1
Optical Fibre ........................................Singlemode
Connector ............................................SC/PC

Primary Optical Launch Power ............-10dBm
Transmit Wavelength...........................1550nm

Primary Optical Sensitivity...................-30dBm
Receive Wavelength............................1310nm

Minimum Optical Dynamic Range .......20dB.

Power Connection

Connector Type ...................................Removable 2-pin, 3.81mm, Screw Terminal
Connector Partno.................................Phoenix 1803578
Supply Voltage.....................................+12 to +15 Volts DC
Maximum Power ..................................2.5 Watts

Data and Alarm Channel Connections

No. of Data Channels ..........................1
No. of Alarms .......................................2

Connectors ..........................................Removable 8-pin, 2.5mm, Spring Terminal
Connector Partno.................................Phoenix 1881383

Data Interface ......................................RS-232, RS-422 or R-S485. Selected by slide switch inside

enclosure. *See appropriate section on how to remove the case
for access to the data switch.

RS-485 – Switch Position - Top
RS-422 – Switch Position - Middle
RS-232 – Switch Position - Bottom

Alarm Outputs Channels 1-2

Each alarm output uses a Solid-state relay, with a maximum load current of 150mA at 125Vac/dc and

Ron < 6.5Ω. 

Summary of Contents for AMG5516

Page 1: ...ta Channel and two Uni directional Alarms for a Singlemode Fibre Link The AMG5516 is a standalone system designed to receive two uni directional alarms and transmit and receive one data signal over a...

Page 2: ...Optical Connection 3 Connections 4 Optical Connections Singlemode 4 Power Connection 4 Data and Alarm Channel Connections 4 Front Panel Indicators 5 Power Opto LED 5 Low Speed Data LEDs 5 Alarm LEDs 5...

Page 3: ...roduction Unit Functional Schematic The AMG5516 transmits 1 data channel to and receives 2 uni directional alarm signals from the AMG5515 transmit unit It also receives 1 data channel transmitted from...

Page 4: ...0dB Power Connection Connector Type Removable 2 pin 3 81mm Screw Terminal Connector Partno Phoenix 1803578 Supply Voltage 12 to 15 Volts DC Maximum Power 2 5 Watts Data and Alarm Channel Connections N...

Page 5: ...n IN IN Data Present IN RS232 Green logic zero V present on input IN Red logic transitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted...

Page 6: ...corresponding mode switch inside the enclosure Every data channel as shipped from the factory is set up for RS 485 operation unless otherwise requested The data input for both the RS 485 and the RS 42...

Page 7: ...middle RS 232 switch bottom 1 IN A IN 2 IN B 3 GND GND GND 4 5 6 7 IN OUT A OUT A 8 IN OUT B OUT B OUT Note A or B in brackets in the above table refers to RS 485 RS 422 data specification Alarm Chan...

Page 8: ...g screws on the rear panel and slide the PCB sufficiently out of the case to enable access to the switch To replace the PCB into the case slide the PCB gently into the case if necessary aligning the b...