AMG AMG5516 Instruction Manual Download Page 1

AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.

Page 1 of 8

AMG5516 Instruction Sheet D20739-
01.doc

AMG5516

Instruction Manual

Receive Unit with one Bi-directional Data Channel and two

Uni-directional Alarms for a Singlemode Fibre Link

The

AMG5516

is a standalone system designed to receive two uni-directional alarms and transmit and

receive one data signal over a Singlemode optical fibre.

The

AMG5516

is designed to be powered using an

AMG2001

standalone power supply.

The

AMG5516

is designed to operate with an

AMG5515

or rackmount equivalent

AMG5515R

transmit

unit in a point to point configuration. The R suffix in the partno. indicates a rackmount configuration.

Summary of Contents for AMG5516

Page 1: ...ta Channel and two Uni directional Alarms for a Singlemode Fibre Link The AMG5516 is a standalone system designed to receive two uni directional alarms and transmit and receive one data signal over a...

Page 2: ...Optical Connection 3 Connections 4 Optical Connections Singlemode 4 Power Connection 4 Data and Alarm Channel Connections 4 Front Panel Indicators 5 Power Opto LED 5 Low Speed Data LEDs 5 Alarm LEDs 5...

Page 3: ...roduction Unit Functional Schematic The AMG5516 transmits 1 data channel to and receives 2 uni directional alarm signals from the AMG5515 transmit unit It also receives 1 data channel transmitted from...

Page 4: ...0dB Power Connection Connector Type Removable 2 pin 3 81mm Screw Terminal Connector Partno Phoenix 1803578 Supply Voltage 12 to 15 Volts DC Maximum Power 2 5 Watts Data and Alarm Channel Connections N...

Page 5: ...n IN IN Data Present IN RS232 Green logic zero V present on input IN Red logic transitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted...

Page 6: ...corresponding mode switch inside the enclosure Every data channel as shipped from the factory is set up for RS 485 operation unless otherwise requested The data input for both the RS 485 and the RS 42...

Page 7: ...middle RS 232 switch bottom 1 IN A IN 2 IN B 3 GND GND GND 4 5 6 7 IN OUT A OUT A 8 IN OUT B OUT B OUT Note A or B in brackets in the above table refers to RS 485 RS 422 data specification Alarm Chan...

Page 8: ...g screws on the rear panel and slide the PCB sufficiently out of the case to enable access to the switch To replace the PCB into the case slide the PCB gently into the case if necessary aligning the b...