AMG Systems Ltd. reserves the right to make changes to this document without
notice. The information herein is believed to be accurate. No responsibility is
assumed by AMG for its use.
Page 6 of 6
AMG2648R Instruction
Sheet D15534-01
See Data or Audio Daughter Board Instruction Sheet for specific data type connections
Removal from the Case
Note: -
The 2600 PCB’s are static sensitive. Handle with proper care and use normal electrostatic
discharge (ESD) procedures. Use properly grounded protection (for example, wrist stamps) when
handling the PCB.
In order to remove the case (to access data and audio interface daughter boards)
1.1. Loosen and remove the four screws on the top and bottom of the unit’s rear panel.
1.2. Slide the PCB assembly connected to the rear panel out of the case.
Ensure that the optical fibre is not trapped.
The data and audio interface daughter boards plug into the appropriate slots on the data motherboard.
When re-inserting the main PCB into the housing take care not to trap the optical fibre or the board
interconnection cables.
Fasten the rear panel with the screws.
Safety
The 2600 series of products uses a Class 1 laser system in accordance with EN 60825-2:2000.
It is always advisable to follow good practice when working with optical fibre systems. This includes:
Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or
connector faces, or point them at other people.
Use only approved filtered or attenuating viewing aids
For other safety issues and advice on good practice associated with the optical fibres systems see EN
60825-2:2000 or your local safety officer.
Maintenance and Repair
There are no user serviceable parts within the AMG2600 products.
In case of problem or failure contact your local support centre or AMG Systems Ltd, Technical Support
Department on tel. +44 (0) 1767 600777.
See unit data sheet for full specification.