Seite 11 von 17
AMG Sicherheitstechnik GmbH
Industriepark Straße A-9
39245 Gommern
Telefon 039200-7797-0
Freecall 0800-2264264*
Fax 039200-7797-29
Geschäftszeiten sind von 8-17 Uhr, außerhalb dieser Zeit ist ein Anrufbeantworter geschaltet
*) kostenlos aus dem deutschen Festnetz und allen deutschen Mobilfunknetzen
SMS commands:
The command to control the fall sensor consists of the abbreviation FL followed by the
desired function, and in the case of
FL1
optionally a comma and the desired sensitivity.
The functions are as follows:
0 = switch off sensor (standard)
1 = SMS
2 = SMS and call
Sensitivity can only be set with
FL1
, with
FL2
the additional call is activated, or if the fall
sensor was deactivated, it is activated with the last used sensitivity level.
Once the call function is activated, the sensitivity can be changed with
FL1,[Sensitivity]
without deactivating the call.
To deactivate the call again, the fall sensor with
FL0
must first be deactivated and can
then be reactivated with
FL1
, or
FL1,[Sensitivity]
.
Sensitivity can be set from
1 to 9
, where 1 is the most sensitive setting and 9 is the
most insensitive, default on delivery 5.
We recommend initially setting the sensitivity to 1 and only gradually reducing it when
there is an increase in unwanted alarms.
Example:
To activate the sensor with SMS sending and maximum sensitivity, the command is:
FL1,1
To activate the sensor with SMS for the last programmed sensitivity, the command is:
FL1
To activate the sensor with call and SMS for the last programmed sensitivity, the
command is:
FL2
To turn off the sensor, the command is:
FL0
battery alarm
If the battery level falls below 20% of its capacity, a message will be sent to the stored
SOS numbers. The battery should then be charged at the next opportunity.
To turn this function on, send the command:
Low1
To turn it off again, send:
Low0