Maintenance and Repair
Page 40 of 60
Easy Ramp and EasyFlex Ramp
6.3
Functionally Testing the Electrically
Operated Belts
Fold the access ramp up to the vertical position, until the
spring-loaded locking bolts audibly engage.
Operate the rocker switch several times (see Figure 6,
page 19). Observe whether the indicator lamp in the red
rocker switch lights up when doing so.
Fold the access ramp out until it rests on the ground.
CAUTION!
Risk of injury and danger of material damage when deploy-
ing the ramp.
There is a risk of injuries to the legs and feet if the ramp is
allowed to fall to the ground out of control. The ramp can be
damaged.
Therefore:
keep hold of the ramp until it is fully in contact with the
ground.
Allow the ramp to deploy slowly.
Operate the rocker switch such that the indicator lamp in
the rocker switch goes out.
Try to pull the electrically-operated belts out.
Operate the rocker switch again such that the indicator
lamp lights up.
Try again to pull the electrically-operated belts out.
The indicator lamp in the rocker switch must only light up
when the ramp is deployed. The electrically operated belts
must only be able to be pulled out when the access ramp is
deployed and the indicator lamp in the rocker switch is lit.
If this is not the case:
Do not use the access ramp and have the access ramp’s
electrical system checked.