20
Z0X-2 Series Z-tron III
TM
Point Level Control
Section 6: Specifications (Continued)
Housing:
The standard explosionproof housing meets the following
classifications:
Nema 1 General-Purpose
Nema 2 Drip-Tight
Nema 3 Weather-Resistant
Nema 4 Waterproof
Nema 5 Dust-Tight
Nema 12 Industrial Use
FM approved for Class I, Groups A, B, C, and D (Div. 1
or 2) and Class II, Groups E, F, and G, (Div. 1 or 2). FM
approval on housing only. If agency approval is required,
use the Drexelbrook PXL The Point™ instrument for point
level control.
Time Delay:
0-60 seconds
Sensing Element:
Sensing
Process
Process
Center
Element
Temperature
Wetted
Rod
Model
and Pressure
Parts
O.D.
Number
700-206-201 250°F @ 200 psi
316 SS and Peek 3/8 inch
Approvals
UL/CUL/508 General Purpose
CE 0344
Temperature at electronics must not exceed 145
° F