Quick Install Guide
TG-PEM Wiring Diagram
(zone connections not shown)
•
The connection from
Telguard Power on the
TG-PEM to the DC
connection on the TG-7
or TG-7FS should be the
ONLY power supply
connection. The AC
power and battery
connectors must NOT
be used. LED8 (AC
Power) should not be
lit.
•
Supervised zones utilize
2.2k
Ω
EOL resistors (not
provided).
STEP-BY-STEP:
1. Register the TG-7 or TG-7FS
Use the dealer portal at www.telguard.com.
2. Pre-configure the TG-PEM prior to installation
Use the Power Expansion Module tab for the device registered.
3. Mount the TG-7 or TG-7FS
Complete all steps of the physical installation as outlined in the
TG-7 series manual. Do not activate yet.
4. Mount the TG-PEM
Tip: To ease mounting of TG-PEM board, pre-thread the metal bracket
using the provided mounting screws (marked in red in diagram)
•
Remove top left mounting screw that holds the TG-7
series board (indicated by arrow).
•
Orient bracket as shown in diagram.
•
Insert bracket at an angle so that top mounting point
slides under board as depicted, and angled tab
threads through the enclosure bump out.
•
Replace screw to securely mount bracket and board.
```
TG-7FS
LTE
Pre-thread using screws
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED8
DC STC2 STC1 TRIP BATT AC
Installing the TG-PEM inside the TG-7 or TG-7FS is simple, but watching our installation
video will get you going in no time and insure your installation is quick and easy.
Scan the QR code or visit
for the installation video and other useful resources
including the full Installation Manual.
TG-7FS
LTE
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED8
Alarm Panel
Burglary Systems
: STC1 needs to
be connected to a 24-hour panel
input zone to indicate alarm
conditions from TG-PEM. STC2
could be used to indicate TG-7
trouble conditions.
Do Not Use
these power
connectors when using TG-PEM
.
Power from TG-PEM
TG-PEM
Panel Power (DC)
DC STC2
STC1
TRIP BATT AC
Fire Systems
: STC1
needs to be connected
to a panel input zone
to indicate all trouble
conditions.