IV.  INITIAL SET-UP 

 

Device Management Utility (DMU) 
 

The SurgeX Device Management Utility (DMU) 
provides the easiest means to find and configure 
your AR for use. The DMU can: 
 

1. Automatically discover multiple ARs on a    
     local network. 
2. Display the current IP address of each AR. 
3. Allow the setting of a new IP address for each AR. 
4. Perform firmware upgrades. 
5. Return an AR to Factory Defaults.

 

 
The SurgeX Device Management Utility is 
available on the SurgeX website at 

http://www.surgex.com 

 
Note:  The IP address can only be set within the 
first 2 minutes after powering up the AR. The 
utility will only work with ARs on the same local 
subnet as the PC. 
 

 

Device 

o

 

Discover:  Automatically discover all 
ARs on the local network. The DMU 
will display the location name of the 
AR, the product ID and version 
number, the current IP address, and the 
MAC address. Factory defaulted ARs 
will display with the name 

Axess 

Ready 

and have an IP address that was 

automatically assigned by the DHCP 
server on your network.

 

-

 

The IP address field also indicates the port for web access that is currently in 
use by the AR. The standard port for web browser accessibility is factory 
default Port 80.

 

 

o

 

Add:  Manually add an AR by IP address.

 

 

o

 

Clear:  Clear the list. 
 

 

 

 

Summary of Contents for Surgex SA-20-AR

Page 1: ...l Support 1 800 645 9721 surgex com 0 Axess Ready Standalone Surge Elimination Power Conditioning SA 20 AR Firmware Version 1 20 261 Software Version 2 00 03 2019 AMETEK Electronic Systems Protection...

Page 2: ...GEMENT UTILITY DMU 5 SETTING THE IP ADDRESS 6 V WEB SERVER 8 PASSWORD 8 CONTROL AND STATUS PAGE 8 SETUP PAGES 9 DEVICE 9 NETWORK 10 Advanced Network 11 AUTOPING 12 SCHEDULE 14 PASSWORDS 15 VI COMMAND...

Page 3: ...s Mode surge elimination and Impedance Tolerant EMI RFI filtering Remote reboot any device monitors routers servers kiosks etc The remote device need not be network attached Conserve energy by powerin...

Page 4: ...___________________ 2019 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com 3 Located on the top panel are Network connection RJ 45 Output receptacles Self Test LED Locat...

Page 5: ...Connection The RJ45 connector for 10 100 Ethernet is situated on the top panel beside the output receptacles The default IP Address is DHCP assigned The fallback IP address is 192 168 1 254 3 AC Power...

Page 6: ...ility is available on the SurgeX website at http www surgex com Note The IP address can only be set within the first 2 minutes after powering up the AR The utility will only work with ARs on the same...

Page 7: ...Discover on This may be necessary for computers with multiple network connections Exit o Exits the DMU program Help o Online Help Opens a web browser to online help resources o About Displays DMU vers...

Page 8: ...eboot command may be used to configure the AR to automatically acquire its network settings from a DHCP server A DHCP server will automatically assign an IP address dynamic address as well as the Subn...

Page 9: ...rol and Status page is displayed Note Only one user may be logged in to the AR at a time Press Power On or Power Off to turn the AC output On or Off In the event of a power outage the AC output will r...

Page 10: ...amount of time the outlet will temporarily be On or Off depending on the initial outlet state Disable Off When checked removes the Power OFF button from the Status and Control page Upgrade Enable Ena...

Page 11: ...allow the AR to automatically acquire its network settings from a DHCP server IP Address Enter a static IP address in dotted decimal format This field will be automatically set if using DHCP Subnet M...

Page 12: ...layed on the Goodbye page It allows use of the public IP address or DNS name instead of the internal IP address of the AR which is the default setting If this setting is left blank the hotlink will be...

Page 13: ...ically reboots if there is no response Ideal for Kiosks and Servers Service monitor AR is installed with the device to be rebooted but pings a remote host to test the communication channel Ideal for D...

Page 14: ...gering AR will power off and remain so until changed via web telnet or DxP Power Off Follow Upon triggering AR will power off When the ping response returns AR will power on Power Cycle Upon triggerin...

Page 15: ...Network Time Server NTS must be specified and enabled in order to use the time scheduling feature A list of public time servers is available at http www ntp org Date Set the initial date for the event...

Page 16: ...supports three modes of user and password operation Login Required Login with password is required for web and telnet access Auto Login No login challenge will be required for any mode of operation un...

Page 17: ...Prompts the user to enter the user name either user or admin Password Prompts the user to enter the password Axess Ready Prompt displayed while logged in Axess Ready Reboot Required Prompt displayed...

Page 18: ...address Yes 192 168 1 254 set subnet dotted decimal Sets the Subnet Mask Yes 255 255 255 0 set gateway dotted decimal Sets the Gateway address Yes 192 168 1 1 set http port 0 65535 Sets the port that...

Page 19: ...ess to be pinged for AutoPing 1 or 2 Yes 0 0 0 0 set autoping 1 2 frequency 1 999 Sets the frequency how often the ping is sent for AutoPing 1 or 2 in seconds Yes 10 set autoping 1 2 failcount 1 999 S...

Page 20: ...mple Current Time 10 14 17 12 20 2011 Server 10 1 2 12 Ok No set time server dotted decimal Sets the IP address of a Network Time Server Yes 64 90 182 55 set time enable yes no Enables or disables the...

Page 21: ...bers to allow for advanced security when AES encryption is used With AES enabled all messages must be encrypted with the AES Passphrase set in the device After the Hello a Command and Response sequenc...

Page 22: ...lasses uName Reserved for future use It will contain the user name of a user on the ipIO that is being accessed password Reserved for future use It will contain the password of the user above desc Com...

Page 23: ...from the server 3 eCmnd_io This command is used to monitor and control the I O on the server 4 eCmnd_keepAlive This command is sent to the server as a means of allowing the client to validate the com...

Page 24: ...geRelays payload see the Payloads subsection for details 0 Successful 1 Error eIO_getRelay This command has not yet been implemented eIO_getRelays This command is used to get the status of all the rel...

Page 25: ...he relay 1 Energize 2 Relax o TChangeRelays typedef struct unsigned char relayStates 32 TChangeRelays Where relayStates is an array of relay states as defined below define NO_CHANGE 0 define ENERGIZE...

Page 26: ...x either Select Device Discover from the menu to locate the ARs on the local network Select Device Add from the menu to manually add the AR by IP address Once the device is displayed in the list highl...

Page 27: ...industry standard rating Maximum Applied Surge Pulse Current Unlimited due to current limiting 8 x 20 s Endurance IEEE C62 41 1991 Category B3 C1 Pulses 1 kV 500 000 3 kV 10 000 6 kV 1000 EMI RFI Fil...

Reviews: