![Ametek Sorensen XFR 1200 Watt Series Operation Manual Download Page 67](http://html1.mh-extra.com/html/ametek/sorensen-xfr-1200-watt-series/sorensen-xfr-1200-watt-series_operation-manual_2931319067.webp)
Using the Shutdown Function
TM-F1OP-C1XN-01
3-9
Using the Shutdown Function
Use the shutdown function to disable or enable the supply’s output so that
you can make adjustments to either the load or the power supply without
shutting off the power supply. Activate this function from the front panel
at any time by using the STANDBY switch. You can also activate it via
remote control through the rear panel J2 Programming and Monitoring
connector, using a 2.5 V to 15 V signal or a transistor-transistor logic
(TTL) compatible signal. The input lines for the Shutdown circuit are
optically isolated.
STANDBY Switch
The STANDBY switch is a press ON/press OFF switch located on the
power supply’s front panel. Push the switch to its IN position to activate
the shutdown circuit. The output voltage and current fall to zero and the
red S/D (Shutdown) LED turns on. Push the switch once more to reset it
to its OUT position and resume normal power supply operation.
Controlling the Shutdown Function via the J2 Connector
The shutdown circuit accepts a 2.5 V to 15 V signal to disable or enable
the power supply output. Make connections for signals at connector J2,
located on the unit’s rear panel. Set rear panel switch SW1-7 to select
signal logic. See
“Rear Panel Connectors and Switch” on page 1–5
more information about making J2 connector and SW1 switch changes.
To activate the shutdown function:
1. Turn OFF the power supply.
2. Connect the signal source to J2 connector terminal 15 (Shutdown
Input/positive) and terminal 14 (Shutdown Return).
3. Set switch SW1-7 to select the desired circuit logic as set out in
4. Turn on the power supply. The power supply will operate as described
in the
Supply Output
, according to the logic that
you select and the level of the input signal. The S/D (Shutdown) LED
on the front panel turns on when the Shutdown circuit is activated.
TM-F1OP-C1XN-01.book Page 9 Thursday, October 25, 2007 9:04 PM
Summary of Contents for Sorensen XFR 1200 Watt Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...This page intentionally left blank ii...
Page 8: ...This page intentionally left blank iv...
Page 10: ...This page intentionally left blank vi...
Page 16: ...xii TM F1OP C1XN 01 book Page xii Thursday October 25 2007 9 04 PM...
Page 18: ...xiv TM F1OP C1XN 01 book Page xiv Thursday October 25 2007 9 04 PM...
Page 30: ...1 12 TM F1OP C1XN 01 book Page 12 Thursday October 25 2007 9 04 PM...
Page 58: ...2 28 TM F1OP C1XN 01 book Page 28 Thursday October 25 2007 9 04 PM...
Page 82: ...4 8 TM F1OP C1XN 01 book Page 8 Thursday October 25 2007 9 04 PM...
Page 94: ...5 12 TM F1OP C1XN 01 book Page 12 Thursday October 25 2007 9 04 PM...