Physical Specifications
Altitude:
2000M (6562 ft.)
Storage Temperature Range:
-55 to +85°C
Humidity Range:
0 to 80% Non-condensing
Time Delay from power on until output stable:
3 seconds maximum
Voltage Mode Transient Response Time:
500
µ
S recovery to 1% band for 30% step load
change from 70% to 100% or 100% to 70%
Remote Start/Stop and Interlock:
TTL compatible input, Contact Closure, 12-250 Vac or
12-130 Vdc
Switching Frequency:
Nominal 70 kHz typical (140 kHz output ripple)
Analog Programming Linearity:
Typical error is less than 0.5% setting.
End users can calibrate the maximum error to 1%.
DISCLAIMER
: Doing this may make the
front panel readings incorrect.
Agency Approvals:
Regulatory NRTL to UL 1012/CSA 107.1
CE compliant (LVD and EMC directives)
Remote Analog Programming (Full Scale Input):
Scales are selectable via an internally-mounted switch.
Parameter
Resistance
Voltage
Current
Voltage
5 k
Ω
5V, 10V
1 mA
Current
5 k
Ω
5V, 10V
1 mA
OVP
5 k
Ω
5V, 10V
1 mA