Asterion DC Multioutput Series
Programming Manual
12-104
M330517-01 Rev C
12.2.1
Program SCPI Command Summary
PROGram<n>
:INITializing?
:CATalog?
:[SELected]
:ARM
:ARM?
:DEFine <step#>,VIMODE,<volts>,<amps>,<ovp>,<sec>
:DEFine
<step#>,RAMPTOV,<volts>,<volts>,<amps>,<ovp>,<sec>
:DEFine
<step#>,RAMPTOC,<volts>,<amps>,<amps>,<ovp>,<sec>
:
DEFine
<step#>,POWERSETTINGS,<watts>,<volts>,<amps>,<ovp>,<sec>
:DEFine <step#>,REPEAT
:DEFine <step#>,SUBCALL, “SEQNAME”
:DEFine <step#>,RETURN
:DEFine <step#>,LOOP,<count>
:DEFine <step#>,NEXT
:DEFine <step#>,STOP
:DEFine <step#>,GOTO, “SEQNAME”
:DEFine <step#>,PAUSE
:DEFine <step#>,NOP
:DEFine? <step#>
:DELete
:SELected
:ALL
:EXECute <value1>,<value2>,<value3>,…,<valueN>
:EXECute VIMODE <NRf> <NRf> <NRf>
:EXECute RAMPTOV <NRf> <NRf> <NRf> <NRf> <NRf>
:EXECute RAMPTOC <NRf> <NRf> <NRf> <NRf> <NRf>
:EXECute POWERSETTINGS <NRf> <NRf> <NRf> <NRf>
:MALLocate DEFAULT
:NAME “name”
:NAME “name”,<chan#>
:NAME?
:SAVe
:SELected
:ALL
:STATe <value>
:STATe?
12.2.2
Program SCPI Command Reference
The letter “C” in the “SCPI” column means that the command syntax is SCPI compliant;
an “N” in the “SCPI” column means that the command syntax is not part of the SCPI
definition and The Data format <n> represents individual channel number.
Command
Description
SCP
I
PROGram
Program subsystem
C
Summary of Contents for Sorensen Asterion DC ASM
Page 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Page 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Page 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Page 162: ...M330461 01 Rev C 14 145...