Figure 3-49: Current Reference Mode channel 3
Entry
Description
INT
Sets the Current Reference Mode into internal for selected channels
Allows user to program the output current through front panel and
digital interfaces.
EXT
Sets the current Reference Mode into external for selected channels.
Allows user to program the output current only through the analog
programming interface.
INT + EXT
Sets the current Reference Mode into in external for selected
channels. Allows user to program the output current through the analog
programming interface, front panel, and digital interfaces.
3.4.6.5
V
OLTAGE
R
EF
M
ODE
Sets the reference mode to either INT (internal) or EXT (eternal) or INT+EXT
(Internal + external) for the selected channels; refer Figure 3-50. The default
reference mode is internal (INT). If EXT is selected as voltage reference mode
for selected channel, respected channel current settings parameter field box
would be disabled and displayed with text EXT; refer Figure 3-19.
Figure 3-50: Voltage Ref Mode channel 1
Figure 3-51: Voltage Ref Mode channel 2