Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-90
Figure 3-139: System Settings Screen (Factory Default)
3.4.11
Warning/Fault Screen
The following warning/Fault screen may appear during supply fault condition, refer to
Figure 3-140. Pressing on View Faults will display all the Fault/Warning description
with an option to clear the Fault. User should press Clear Fault button from the clear
fault screen (refer Figure 3-141) to continue the operations of the power supply and
clear the fault.
These warnings indicate description of Faults which has occurred in a power module,
refer Table 3-3. These conditions might clear themselves, however, if they continue
to occur after pressing the clear Fault; refer Figure 3-141. contact the factory for
service assistance.
Figure 3-140: Fault Screen
Figure 3-141: Clear Fault Screen
Mentioned below are the
power supply’s fault conditions:
Fault
Description
Action
OVP FAULT
Output voltage
exceeded Over Voltage
trip limit.
Check sufficient margin between set voltage and Over
Voltage Protection limit.