background image

User Manual

3

TEMPERATURE MEASUREMENT OPTION

T = YES 

LEAVE BLANK = NO

CABLE SEAL

V = VITON 

N = NEOPRENE

FILL FLUID

S = SILICONE OIL (STANDARD)

DIAPHRAGM MATERIAL

L = 316L STAINLESS STEEL

ELECTRICAL CONNECTION OPTION 

N = POLYURETHANE CABLE (K515136)/NUT

R = POLYURETHANE CABLE (K515136)/NUT/CABLE SUPPORT BRACKET

C = POLYURETHANE CABLE (K515136)/CONDUIT ADAPTER

E = POLYURETHANE CABLE (K515136)/EMI/NUT

F = POLYURETHANE CABLE (K515136)/EMI/CABLE SUPPORT BRACKET

G = POLYURETHANE CABLE (K515136)/EMI/CONDUIT ADAPTER

O = POLYOLEFIN CABLE (K515101)/NUT

Y = POLYOLEFIN CABLE (K515101)/NUT/CABLE SUPPORT BRACKET

W = POLYOLEFIN CABLE (K515101)/CONDUIT ADAPTER

T = TEFLON CABLE (K515075)/NUT

S = TEFLON CABLE (K515075)/NUT/CABLE SUPPORT BRACKET

V = TEFLON CABLE (K515075)/CONDUIT ADAPTER

X = TEFLON CABLE (K515075)/EMI/CONDUIT ADAPTER

PRESSURE CODE

XXXX = PRESSURE RANGE (PSI)

BXXX = PRESSURE RANGE (BAR)

INPUT/OUTPUT

B = 11-30 VDC / 4-20 MA 

C = 9-30VDC / 1-6VDC 

D = 9-30VDC / 1-5VDC 

E = 9-30VDC / 0.5-4.5VDC 

F = 9-30VDC / 0-5VDC 

G = 5VDC / 0.8-3.2VDC (RATIOMETRIC FROM 4.75 TO 5.25VDC INPUT) 

H = 5VDC / 1-6VDC (RATIOMETRIC FROM 4.75 TO 5.25VDC INPUT) 

J = 9-30VDC / 0.25-2.75VDC 

R = 5VDC / 1-6VDC (RATIOMETRIC FROM 4.75 TO 5.25VDC INPUT)

SENSING PORT

S = DELRIN SNUBNOSE

SDT - SUBMERSIBLE DIGITAL TRANSDUCER

 SDT S B 

0015 

N L S V T

Model Number And Ordering Information

EXAMPLE: To specify the Model SDT Submersible Transmitter with 11-30V Input  
and 4-20mA Output, having to measure 15psi (34.6 Ft water), with a standard nut 
and polyurethane cable  & electrical connection, 316 stainless steel diaphragm, 
silicone oil fill, Viton grommet and 100 feet of cable:   SDTSB0015NLSV (100ft cable)
NOTES:
1)  Cable Termination side should be located in a dry termperature  

stable environment.

2) Damage will result if submerged in frozen liquid.
3)  A fused or crrent limited DC power source is recommended  

to prevent damage during fault conditions.

4) Shield is tied to case on EMI versions only
5) Additional pressure ranges are available, consult factory.

Notes:
1) Cable Termination side should be located in a dry temperature stable environment.
2) Damage will result if submerged in frozen liquid.
3) A fused or current limited DC power source is recommended to prevent damage during fault conditions.
4) Shield is tied to case on EMI versions only
5) Additional pressure ranges are available, consult factory.

Example: To specify the Model SDT Submersible Transmitter with 11-30V Input and 4-20mA Output having to 
measure 15psi (34.6 ft/water) with a standard nut and polyurethane cable & electrical connection, 316ss Dia-
phragm, silicon oil fi ll, Viton grommet and 100 ft of cable: SDTSB0015NLSV (100ft cable)

WIRE LEGEND

COLOR 

TEFLON

COLOR POLY-

URETHANE/

POLYOLEFIN

 VOLTAGE 

OUTPUT

CURRENT 

(R-20MA) 

OUTPUT

RED

RED

+Vin

+Vin

BLACK

BLACK

–Vin

–Vin

WHITE

WHITE

Vout

N/A

GREEN

GREEN

CASE GROUND

BLUE

BLUE

TEMPERATURE

ORANGE

BROWN

STANDARD PRESSURE RANGES*

PSI

BAR

Reference Equivalents

0001

B0.2

0-2.31 ft water

0-0.7 m water

0006

B0.4

0-13.8 ft water

0-4.2 m water

0015

B001

0-34.6 ft water

0-10.5 m water

0030

B002

0-69.2 ft water

0-21.1 m water

0060

B004

0-138 ft water

0-42.2 m water

0100

B007

0-230 ft water

0-70.3 m water

0150

B010

0-345 ft water

0-105.4 m water

Reviews: