background image

15020-101 Rev-D

Page  8

1.  ON/OFF Button (MAIN)

 

Press to turn the instrument on and off.  The  
PDM turns off after one minute to ensure  
longer battery life.

2.  Measurement Slide Controls

 

Used to move the index lines that indicate 
Pupillary Distance and Right/Left Nose-to-
Pupil Distance measurements.   

3.  Distance Dial

 

Rotate to measure inter-pupillary distance at 
various distances, from infinity to 30 cm. 

4.  PD/LD button

 

Changes between pupil distance (PD) and 
vertex distance (LD) modes.

5.  LCD Screen

 

Measurement data is displayed on the LCD.

6.  Viewfinder

 

Operator looks through the viewfinder to see 
the index lines and the patient’s eyes.

7.  Magnification Switch

 

Changes the view magnification to suit the 
operator.

8.  Patient Windows

 

The patient views the fixation target through 
these windows.

9.  Nose Support

 

Used to stabilize the PDM against the pa

-

tient’s nose.

10.  Forehead Support

 

Used to stabilize the PDM against the pa

-

tient’s forehead.

11.  Battery Compartments

 

Accepts 2 AA batteries in each side.

12.  R/L Occluder lever

 

Used to occlude the right or left eye for mon-
ocular nose to pupil distance measurement.

Features and Functions

Summary of Contents for Reichert PDM

Page 1: ...PDM Digital PD Meter User s Guide...

Page 2: ...in the product described in this manual without notice and without incorporating those changes in any products already sold ISO 9001 13485 Certified Reichert products are designed and manufactured un...

Page 3: ...for Use 9 Turning on the PDM 9 Calibration Verification 9 PD Measurement 9 Monocular PD Measurement 9 Adjustable Distance PD Measurement 9 Vertex Distance Measurement 10 Cleaning Maintenance 11 Cleani...

Page 4: ...TRAINED BY REICHERT OR SERIOUS INJURY TO THE OPERATOR OR PATIENT MAY OCCUR WARNING MODIFICATIONS TO THIS INSTRUMENT ARE NOT ALLOWED ANY MODIFICATION TO THIS UNIT MUST BE AUTHORIZED BY REICHERT OR SER...

Page 5: ...ON TO THE RISK OF DAMAGE TO THE PRODUCT CAUTION DO NOT USE SOLVENTS OR STRONG CLEANING SOLUTIONS ON ANY PART OF THIS INSTRUMENT AS DAMAGE TO THE UNIT MAY OCCUR SEE MAINTENANCE SECTION FOR DETAILED CLE...

Page 6: ...in this User s Guide Consult Instructions for Use REF Catalog Number SN Serial Number Type B Product Classification Class II Equipment 2015 Date of Manufacture Waste of Electrical and Electronic Equip...

Page 7: ...guide to ensure optimum performance of your new instrument Properly trained eyecare professionals such as ophthalmologists optometrists opticians and eye care technicians should operate this instrume...

Page 8: ...ance LD modes 5 LCD Screen Measurement data is displayed on the LCD 6 Viewfinder Operator looks through the viewfinder to see the index lines and the patient s eyes 7 Magnification Switch Changes the...

Page 9: ...at the contact information in the Introduction section of this manual PD Measurement 1 Set the Distance Dial to infinity 2 Carefully position the instrument in front of the patient using the Nose and...

Page 10: ...ctive patient windows 3 Approach the patient s head from the side and position the PDM so that the fixed index line appears to be touching the front of the cornea 4 Position the Forehead Support again...

Page 11: ...necessary apply a small amount of clean water to a clean soft cloth to remove any residual soap solution 3 Dry the exterior using a clean soft cloth 4 Isopropyl alcohol may be used to clean the Foreh...

Page 12: ...cular 46 82mm 0 5 mm 0 5mm steps Monocular 23 41mm 0 5 mm 0 5mm steps Vertex 5 23mm 0 5 mm 0 5mm steps Distances 30cm Infinity Disposal This product does not generate any environmentally hazardous res...

Page 13: ...e or handling of the product If notified promptly in writing of any action brought against the purchaser based on a claim that the instrument infringes a U S Patent Reichert will defend such action at...

Page 14: ...15020 101 Rev D Page 14 Notes...

Page 15: ...Page 15 15020 101 Rev D Notes...

Page 16: ......

Reviews: