3 - 5
Landscan LSP-HD
Infrared Linescanning System
Installation Overview
Dimensions
All dimensions in mm/in
3.4 Enhanced Water Cooled Mounting System - Part Nº 800095
The Water Cooled, Air Purged Base Plate is used
in applications where an LSP-HD Linescanner is to
be installed into environments where the ambient
temperatures are in the range of 60 to 120 °C
/ 140 to 248 °F. It is ideally suited to general
industrial applications.
The air purge facility should be utilised where
the operating environment is dusty and airborne
particles could contaminate the scanner viewing
window. The plate provides a quick release
mounting arrangement for the scanner, making
realignment a simple and easy operation.
Specifications
Maximum Ambient Temperature
120 °C / 248 °F
Cooling Water Requirements
1.5 to 2 litre per min / 0.4 to 0.53 US gal per min @
30 °C / 86 °F
Maximum Water Pressure
5.88 Bar / 85 PSI
Cooling Water Connection
¼” BSP for 9.5 mm / 3/8 in bore water hose
Air Purge Requirements
300 litre per min / 12.36 cu ft per min
Air Purge Connection
G3/8 suitable for 38 mm / 1.5 in inner diameter neo-
prene hose
Weight
8.4 kg / 18.5 lb
Dimensions (l x w x d)
393 x 275 x 240 mm / 15.47 x 10.83 x 9.45 in
Mounting Holes
Ø 8.5 mm / 0.34 in to accept M8 screws
Summary of Contents for LANDSCAN LSP-HD
Page 4: ...Infrared Linescanning System Installation Overview Landscan LSP HD Blank ...
Page 6: ...INTRODUCTION 1 ...
Page 9: ...TYPICAL SYSTEM CONFIGURATIONS 2 ...
Page 10: ...Infrared Linescanning System Installation Overview Landscan LSP HD Blank ...
Page 26: ...MOUNTING ACCESSORIES 3 ...
Page 34: ...BLOWERS 4 ...
Page 36: ...POWER SUPPLIES 5 ...
Page 40: ...CABLES 6 ...
Page 42: ...SOFTWARE SETUP 7 ...
Page 68: ...MAINTENANCE SERVICE 8 ...
Page 70: ......