Page 1: ...Target Orbiting Thermometer User Supplement User Supplement Land Instruments International 2008 2017 Issue 5 13 March 2017 Publication N 198 176 Language English...

Page 2: ...e user documentation supplied before installing and operating the equipment The safety of any system incorporating this equipment is the responsibility of the assembler Protective Clothing Face and Ey...

Page 3: ...ent damage during transit You must include a written report of the problem together with your own name and contact information address telephone number email address etc Design and Manufacturing Stand...

Page 4: ...Target Orbiting Thermometer User Supplement...

Page 5: ...Target Orbiting Thermometer Contents 1 About this Supplement 1 2 UNO Target Orbiting Thermometers 1 2 1 Supplementary Specification 1 3 Principle of Operation 3 3 1 Suggested settings for use in Peak...

Page 6: ...K 1K Temperature C Specification C U2 U2 TO U1 U1 TO 300 0 Not Specified Not Specified 400 0 2 7 4 4 500 0 2 9 4 9 600 0 3 2 5 4 Not Specified Not Specified 700 0 3 4 5 9 3 9 7 8 800 0 3 7 6 4 4 3 8...

Page 7: ...View U1 600 1600 CV TO 100 1 U1 600 1600 CS TO 100 1 U1 1100 2900 FV TO 100 1 U1 1100 2900 FS TO 100 1 U1 800 2600 CV TO 200 1 U1 800 2600 CS TO 200 1 U1 1500 4700 FV TO 200 1 U1 1500 4700 FS TO 200 1...

Page 8: ...d target spot diameter D 100 D 200 for high temperature versions rad D 29 D Distance to Target Plane d target spot diameter identical to a standard thermometer 2 Optical Field of View D d Fig 1 Field...

Page 9: ...ion is designed for use on moving or intermittent targets In a standard UNO Thermometer the eyepiece graticule defines the target spot diameter In a Target Orbiting Thermometer the graticule defines t...

Page 10: ...500 4700 FV 200 1 1 5 x target spot diameter U1 1500 4700 FS 200 1 1 5 x target spot diameter U2 300 1100 CV 100 1 1 2 x target spot diameter U2 300 1100 CS 100 1 1 2 x target spot diameter U2 600 200...

Page 11: ...ruments based on System 4 UNO thermometers accessories and mountings and special instruments based on UNO Application dedicated processors based on LANDMARK Graphic ABTS S and ABTS U FTS VDT S and VDT...

Page 12: ...utside the Ambient Temperature Humidity and Vibration rating of the product environmental contamination solvent vapours deposition of airborne contamination cooling liquids of non neutral pH etc overh...