background image

User Manual

Industrial Pressure Indicator

AMETEK JOFRA IPI Mk. II

Summary of Contents for JOFRA IPI Mk. II

Page 1: ...User Manual Industrial Pressure Indicator AMETEK JOFRA IPI Mk II...

Page 2: ...2 0 IPI Mk II Display and Controls 4 3 0 Operation 4 4 0 Supervisory Mode 6 5 0 Normal Operation 7 6 0 Changing the Batteries 8 7 0 Cleaning 8 8 0 Specifications 9 9 0 Service Center Calibration or Re...

Page 3: ...rom IPI Mk II including export of run data to text comma separated values CSV and Excel files Clear logged data in IPI Mk II 1 1 Contacting Ametek Sales Service Offices AMETEK MCT North America Tel 1...

Page 4: ...rtified by CSA as conforming to relevant Canadian and USA standards Conforms to relevant European Union directives Wheeled bin conforms to EC directive 2002 96 EC Hazard Location Information Approvals...

Page 5: ...I Mk II is not intended for use with flammable substances and is intended for installation only in locations providing adequate protection against the entry of solid foreign objects or water capable o...

Page 6: ...to display PSI By pressing the and ZERO and MAX MIN keys you can scroll forward and backwards through the 18 standard engineering units plus a one custom unit scale When the desired unit is displayed...

Page 7: ...second Note that 10 sec provides the fastest response time 7 Set TARE This allows you to set a constant offset value which is then subtracted from the measured pressure For example if a TARE is set at...

Page 8: ...adjustment enable disable Damping settings enable disable Sample rate setting enable disable Tare setting enable disable Custom engineering units set scale factor 4 Use the CONFIG key to scroll throug...

Page 9: ...ng the MAX MIN button once will display the minimum pressure from memory Pressing the MAX MIN button again will display the maximum pressure from memory After about 2 seconds the gauge returns to norm...

Page 10: ...se with the backlight off With intermittent use batteries could last a year or more There is a low battery icon in the upper left of the display It will appear when battery level is low Replace batter...

Page 11: ...000 and 5 000 PSI 70 to 350 bar ranges 2X input pressure range 10 000 PSI 700 bar 1 5X input pressure range Overload Alarm indicate OL on display 1 2X input pressure range Temperature Compensation Fu...

Page 12: ...rs at slow sample rate Low Battery Indicator icon is displayed near the end of battery life 9 0 Service Center Calibration or Repair Only qualified service personnel should perform calibration repairs...

Page 13: ...1 5 15515 25858 51715 inHg 0 C 2 03602 2 0360 30 540 61 081 203 60 610 81 1018 0 2036 0 4072 0 6108 1 10180 20360 cmH 2 O 4 C 70 3089 70 309 1054 6 2109 3 7030 9 21093 35154 70309 cmH 2 O 20 C 70 4336...

Page 14: ...LT Returns an error code from the error queue IDN Identification query Returns the manufacturer model number and firmware revision level of the Calibrator TARE Tares the offset pressure of the reading...

Page 15: ...TEMP_UNIT Used to set temperature unit TEMP_UNIT Returns temperature unit Parameter Units Units Meaning Psi Pressure in pounds per square inch Bar Pressure in bars mBar Pressure in millibars Kg cm2 P...

Page 16: ...e not connected 12 0 Warranty According to current terms of sale and delivery This warranty only covers defects in manufacture and becomes void if the instrument has been subject to unauthorised inter...

Page 17: ..._ Temp Sensor Service request This instrument is sent for calibration input please tick off ___ Calibration as left ___ Check ___ Calibration as found and as left ___ Service ___ Accredited calibratio...

Page 18: ......

Page 19: ...SPK IPI 004 0200044 Rev A ATEX 10 12...

Page 20: ...surement tasks from handheld field instruments to laboratory reference level bench top instruments JOFRA JF Marine Instruments A complete range of calibration equipment for temperature pressure and si...

Reviews: