Chapter 9: Specifications
Installation and Maintenance Manual
26
Chapter 9: Specifications
9.1: 1995 Micro-Set PLS Programmer
9.2: Mechanical Relay
(Single Pole, Double Throw)
Resolution
-12 Bit (4096)
Scale Factor
-360 or 1,000
Scan Time
-Standard 285 µseconds
Temperature
-32°F to 125°F (Operating)
Range
-0°F to 150°F (Storage)
Operating Voltage
-110/120V AC 50/60 Hz 300 mA
INPUTS
Transducer
-Resolver accurate to ±3 arc minutes provides resolution of 1
part in 4096, 2800 RPM maximum speed.
Logic
-Fault check and security 5V DC at 10mA. May be operated
by isolated contact, current sourcing or current sinking device.
OUTPUTS
-Plug-in relays listed below
Contact Relay
-10 Amp Isolated Contact
Pick-Up
-2 ms
Drop-Out
-15 ms
9.3: AC Solid-State
(Single Pole, Normally Open)
Maximum Load
-1 Amp
Load Voltage Range
-70 - 250V AC Zero Voltage Switching
Leading Current
-3 mA at 120V AC
Voltage Drop w/Output On
-3.0V RMS or Less
Inputs
-N.O. and Common
Operate & Reset Time
-1/2 cycle of line voltage max. +1ms or less
www.comoso.com