Ametek CHANDLER ENGINEERING 7360V Instruction Manual Download Page 21

SECTION 5 

 REPLACEMENT PARTS     5-1  

 
 

 

Section 5 

 Replacement Parts 

 

Part Number 

Description 

04237-24 

Fuse Holder 

19-0057 

Thermocouple Assembly 

07-0454 

Cooling Coil Seal, Copper 

7750-0213 

Rear Cover 

7750-0232 

Front Cover 

98-0103 

Cylinder Plug 

98-0106 

Cylinder 

98-0112 

Seal Ring 

98-0117 

Cooling Coil, Cylinder Assembly 

98-0210 

Mold Assembly 

98-0500 

Cabinet Assembly 

98-0505 

Cylinder Mounting Base 

98-0506 

Cylinder Base 

98-0506 

Pressure Gauge 

98-0511 

Top Panel 

98-0512 

Cylinder Mounting Ring 

98-0515 

Wiring Diagram 

98-0516 

Valve Decal 

C07357 

Insulation, Cylinder 

C08101 

Pump 

C11062 

Controller,Temp,Limit 1000F,Type J 

C08103 

Back Pressure Valve 

C08104 

O-Ring 

C08105 

Retaining Ring 

C08106 

On/Off Rocker Switch 

9050-7360V 

Controller,Temp,7360V 

P-1764 

Rupture Disk 

P-2859 

Filter 

 
 
 
 

Summary of Contents for CHANDLER ENGINEERING 7360V

Page 1: ...DEL 7360V VERTICAL CURING CHAMBER Revision G APRIL 2021 98 0520 S N ____________ 2001 N Indianwood Ave Tulsa Oklahoma 74012 U S A TEL 918 250 7200 FAX 918 459 0165 E mail chandler sales ametek com Web...

Page 2: ...publisher assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein This publication contains the follo...

Page 3: ...dures 2 1 Power Switch 2 1 Model 7050 Temperature Controller 2 1 Drain Cylinder Fill Cylinder switch 2 2 Heater Switch 2 2 Pressurize Cylinder Switch 2 2 Cool Cylinder Switch 2 2 Cylinder Drain Valve...

Page 4: ...T i i TABLE OF CONTENTS Section 4 Maintenance and Servicing 4 1 Maintenance 4 1 Troubleshooting 4 1 Section 5 Replacement Parts 5 1 Section 6 Drawings and Schematics 6 1...

Page 5: ...essure in the instrument above a desired lower limit If the instrument pressure drops below the lower limit the pump will increase the pressure back up above the lower limit High temperature alarm If...

Page 6: ...fication The primary high pressure sealing element is the metal seal ring 2 As the pressure inside the cylinder increases the seal ring is wedged between the plug 1 and the cylinder forming a tight me...

Page 7: ...seal failure and the release of hot water or steam Where to Find Help In the event of problems the local sales representatives will be able to help or the personnel at Chandler Engineering can be cont...

Page 8: ......

Page 9: ...is also required at pressures between 20 and 40 psi 135 275 kPa All air water and steam fittings have inch NPT threads Connect air supply line to the fitting on the rear of the instrument marked AIR...

Page 10: ...be connected to an appropriately rated power source The earth ground connection on the rear of the instrument should be connected to a metal water pipe a metal rod driven in the ground or other approp...

Page 11: ...w plug O ring if the cylinder temperature has exceeded 350 F 177 C Control Panel Functions Figure 2 shows how the front control panel is designed You may find it convenient to refer to this figure as...

Page 12: ...switch The COOL CYLINDER switch controls the flow of water to the internal cooling coils This switch should always be in the OFF position during a test and then switched to the ON position at the comp...

Page 13: ...vel The PUMP PRESSURE ADJUST may also be used to slowly and quietly increase the cylinder pressure This is done by turning the PUMP PRESSURE ADJUST knob clockwise while the PRESSURIZE CYLINDER switch...

Page 14: ......

Page 15: ...en thoroughly lubricated with Moly grease or similar high temperature lubricant Note Install a new O ring after any test in which the temperature exceeds 350 F 177 C Check internal O ring on bottom of...

Page 16: ...The trapped air can be removed by loosening the 5 8 hex plug in the top of the cylinder 3 Turn the HIGH PRESSURE LIMIT REGULATOR knob out counterclockwise until the pressure begins to drop The upper l...

Page 17: ...curs the yellow pushbutton switch will light and the heaters will cease to operate The only way to reset this alarm is by pressing the lighted switch on the front panel If a TEMPERATURE LIMIT ALARM oc...

Page 18: ...ter to steam Draining the Cylinder 1 Turn all valves to the OFF position 2 Turn the PRESSURIZE CYLINDER and FILL CYLINDER switches to the OFF position 3 Open the CYLINDER DRAIN valve 4 Turn the DRAIN...

Page 19: ...ce Make certain that the plug and cylinder threads are clean and well lubricated with Moly grease or other high temperature lubricant Check the internal plug O ring periodically for cuts tears or dete...

Page 20: ...locked with cement Leak in cylinder or tubing Damaged valve or pressure regulator seat Pressure regulator is blocked with cement Wrong tuning parameters Malfunctioning controller High Pressure Limit r...

Page 21: ...ing Coil Cylinder Assembly 98 0210 Mold Assembly 98 0500 Cabinet Assembly 98 0505 Cylinder Mounting Base 98 0506 Cylinder Base 98 0506 Pressure Gauge 98 0511 Top Panel 98 0512 Cylinder Mounting Ring 9...

Page 22: ......

Page 23: ...SECTION 6 DRAWINGS AND SCHEMATICS 6 1 Section 6 Drawings and Schematics Drawing Number Description 98 0006 Piping Schematic 98 0518 Wiring Diagram...

Page 24: ...CHANDLER ENGINEERING...

Page 25: ......

Page 26: ...ften are ________________________________________________ ______________________________________________________________________________ Other comments ________________________________________________...

Page 27: ...cut out postcards on dotted lines...

Page 28: ...bnormal usage faulty installation im proper maintenance or any repairs other than those provided by authorized Chandler Engineering personnel This warranty is in lieu of all other warranties expressed...

Reviews: