CT3 TEXTURE ANALYZER

Operating Instructions

Manual No.

 

M08-372-F1116

Summary of Contents for BROOKFIELD CT3

Page 1: ...DIVISION 11 Commerce Boulevard Middleboro MA 02302 USA Tel 508 946 6200 or 800 628 8139 USA excluding MA Fax 508 946 6262 Internet http www brookfieldengineering com CT3 TEXTURE ANALYZER Operating In...

Page 2: ......

Page 3: ...ting Menu 15 III 7 Running A Test 17 NORMAL Test 18 HOLD TIME Test 19 CYCLE COUNT Test 20 BLOOM Test 21 TPA Test 22 TENSION Test 23 TARGET HOLD TO LOAD Test 24 SURIMI Test 28 III 8 Global Parameters 2...

Page 4: ...cterstics of Biscuits Cookies 41 V 3 Review of Solid Chocolate at Ambient Temperature 43 Appendix A Probes Fixtures Calibration Accessories and Gelatin Accessories 46 A 1 Probes 46 A 2 Fixtures 50 A 3...

Page 5: ...n tension using grips The resistance of the material to these forces is measured by a calibrated load cell and shown in either grams or Newtons These forces are a function of the properties of the sam...

Page 6: ...s the SI system of units for all parameters Parameter Unit Abbreviation Load Grams or Newtons g or N Deformation Millimeter mm Time Seconds s Speed Millimeter per second mm s Work MilliJoules mJ I 4 S...

Page 7: ...speed using the Select Scroll knob can be switched between 0 1mm s and 1 0mm s by depressing Reset Stop button Temperature 20 C to 120 C Requires optional probe DVP 94Y Output RS232 Compatible Serial...

Page 8: ...within the appropriate range as shown on the model and serial tag of the instrument located on the back of the CT3 The CT3 Texture Analyzer must be earth grounded to ensure against electronic failure...

Page 9: ...nment In case of emergency turn off the instrument and then disconnect the electrical cord from the wall outlet The user should ensure that the substances placed under test do not release poisonous to...

Page 10: ...f descent SELECT SCROLL see section III 6 This knob has multiple functions 1 The knob is pressed to select the option currently highlighted 2 The knob is rotated to change the value of the parameter b...

Page 11: ...P N DVP 94Y 4 Power Entry Module ON OFF switch fused see I 2 Utilities Voltage 90 265 VAC I 8 Cleaning Instrument and Keypad Clean with a dry nonabrasive cloth Do not use solvents or cleaners Probes...

Page 12: ...elected probe See Section IV 2 for more information 4 SetthetestmodetoNormal PleasereviewSectionIII 6fordetailedexplanationofoperation of Select Scroll knob 5 Set the trigger value as recommended belo...

Page 13: ...on load cell Be sure to place only the sample for test under the probe Keep body parts and clothing away from the probe during the test The CT3 Texture Analyzer uses controlled forces to evaluate a m...

Page 14: ...very test Fixture Base Table TA BT KIT Fixture Base Table TA RT KIT FIne Adjustment Knob Locking Knob Figure III 2 See Appendix A for fixtures which can be used with each Base Table Rotary Base Table...

Page 15: ...lt Choice of a probe must be made with consideration toward the purpose of the test and the nature of the sample The probes may be cleaned while attached to the CT3 Follow recommendations in Section I...

Page 16: ...are fixed according to industry standard TPA Test Requires trigger deformation speed Tension Test Requires trigger deformation speed Hold to Load Test Requires trigger target load speed Static Load Te...

Page 17: ...to get to the tenths digit and depress it again to leave the value at 0 A data entry of zero in all columns for any parameter will result in that parameter being reset to the previous value Pressing...

Page 18: ...button or reset button is pressed The reset button will return the instrument to the default display where the test mode may be selected The start button will begin the same test again A test may be r...

Page 19: ...TEMP XXX X F Figure III 8 Peak load is reported as the maximum measured load during the test Deformationatpeakisthedistancetowhichthesamplewascompressedwhenthepeakloadoccurred Work is defined as the...

Page 20: ...value target deformation and test speed using the Hold Time menu screen TEST HOLD TIME XXXX S TRIGGER XXX X g DEFORMATION XXX X mm SPEED XX X mm S Figure III 10 A hold time test performs a single com...

Page 21: ...menu screen TEST CYCLE COUNT XXXX TRIGGER XXX X g DEFORMATION XXX X mm SPEED XX X mm s Figure III 13 When the operator depresses the start button the cycle count test performs multiple compressions on...

Page 22: ...ormation of 4mm During the test the running screen is seen as shown below TEST BLOOM DEFORMATION XXX X mm LOAD XXXX X g Figure III 17 Both Deformation and Load displays are live during the test The pr...

Page 23: ...X mm ADHESION XXXX X mJ TEMP XXX X F Figure III 21 Hardness1 is the peak load of the first compression cycle Hardness2 is the peak load of the second compression cycle Cohesiveness is the ratio of A2...

Page 24: ...clamped Rotate knob to move 1mm click or hold knob down to descend at 4 5mm s ADJUST POSITION USING SCROLL SELECT PRESS START DEFORMATION XXX X mm Figure III 24 The deformation value shown in this scr...

Page 25: ...nput a Hold Time The time is entered as whole seconds the HOLD TIME field length is four digits long Trigger force and Target Load entries conform to the load cell type of the instrument as shown in F...

Page 26: ...ry The cursor will reposition over the right most digit of the speed data field The speed field will retain its previous value unlike Hold Time Trigger Load and Target Load Rotating the Select Knob wi...

Page 27: ...TRIGGER load will override the PRE SPEED setting for the probe with a default speed of 4 5 mm sec known as jogging The DISTANCE remains at 0 0 until the TRIGGER load value is reached when the probe ma...

Page 28: ...Knob returns the display to the RUN screen Activating the EMERGENCY STOP knob will terminate the test and return the probe to the HOME position Pressing the STOP button will also abort the test retra...

Page 29: ...o the HOME starting position NOTE This test is only available in CT3 instruments with load cells up to 4500g and firmware version 2 0 or higher The operator may set the trigger value correction value...

Page 30: ...ewtons After Autozero during startup rotate the Select Knob to reach the GLOBAL PARAMS screen then press the Select Knob to access the data entry function There are some parameters that affect every t...

Page 31: ...tests III 9 1 NORMAL mode pre positioning The pre positioning screen is displayed after theATTACH PROBE screen The probe can be moved downwards or upwards by rotating the Select Knob Pressing the Sele...

Page 32: ...the STOP button at this time will display the setup screen This places the CT3 back at the NORMAL setup mode The probe will return to the HOME position The various setup parameters can be modified an...

Page 33: ...creen This places the CT3 back at the CYCLE COUNT setup mode The probe will return to the HOME position The various setup parameters can be modified Pressing START will begin the full test run complet...

Page 34: ...software CD After installing this software into a computer you can add up to 10 additional test programs to the CT3 menu based upon any one of the test methods described above For example suppose you...

Page 35: ...The Hanger is part of the calibrated weight set and it has a calibrated weight value This weight must be included as part of the total weight applied to the load cell Attach the desired weight to the...

Page 36: ...Load Cell Capacity 4500 1 2 3 4 5 Load Cell Accuracy Mass 999 84 994 04 993 96 994 05 497 12 22 5g Serial 59 87 92 106 153 Weight 1 999 84 1 2 1993 88 1 2 3 2987 84 1 2 3 4 3981 89 1 5 4479 00 INSTRUC...

Page 37: ...le a material that has a flat surface offers a consistent interface with the probe even if the material is not centered in the test fixture If your test sample is uneven part of the test method could...

Page 38: ...res The Trigger Point establishes the minimum load required to begin the test This is how the CT3 knows when the probe is touching the sample This parameter should be set to a low value for a material...

Page 39: ...an ideal method for the assessment of yogurts and other gelled semi solidfoods Thiscompressionextrusiontestconsistsofapplying a force to the product until it flows through the space between the probe...

Page 40: ...o characterized by the failure to form sample fracture and the absence of peaks within the curve Thefat freesamplehasamuchsteeperinitialgradientandsubsequentlyhigher values for all measured parameters...

Page 41: ...r more bound consistency of the product EMPIRICAL Test conditions which will affect results generated FACTORS 1 Sample size 2 Sample age 3 Sample temperature 4 Base and edge effects 5 Sample container...

Page 42: ...testalingofproductlife bakecharacteristicsthroughquantification of hardness at different points within the biscuits circumference or any other application specific to your organization CT3 SETTINGS MO...

Page 43: ...variations in formulation composition and process conditions imposed Please note that if inclusions such as chocolate chips or oats are in the biscuit they will contribute directly to result fluctuati...

Page 44: ...SPEED 0 1 mm s DISTANCE 2 4 or 6 mm PROBE REF Stainless steel needle probe 10 Taper Ref TA9 Confectionery holding rig TA CJ METHOD Samples were removed from wrappers and broken into individual chunks...

Page 45: ...fferentiation CONCLUSIONS This empirical procedure generates key information related to chocolate hardness and consistency while additional information relating to adhesion is also acquired Adhesion f...

Page 46: ...8mm cylinder TA25 1000 0 33mm cutting wire TA53 2mm rod TA39 38 1mm cylinder TA4 1000 6mm cylindrical TA41 25 4mm ball TA43 4mm cylinder TA44 and TA PCC TA P KIT3 CURD PROBE KIT Includes the followin...

Page 47: ...ROBE Black Delrin 20mm Long TA36 7mm DIAMETER CYLINDER PROBE Stainless Steel 35mm Long TA39 2mm DIAMETER ROD PROBE Stainless Steel 5g 20mm Long Flat End Margarine TA40 4 5mm DIAMETER ROD PROBE Stainle...

Page 48: ...Diameter TA29 15 CONE PROBE Stainless Steel 8mm Diameter TA32 100 90 CONE PROBE Clear Acrylic 30mm Diameter Low mass for CT3100 TA32 1000 90 CONE PROBE Clear Acrylic 30mm Diameter TA PCC PROBE CARRYIN...

Page 49: ...lar samples up to 5mm thick Each grip clamps from both sides of sample with two opposing thumbscrews for precise alignment Includes one pair of T Bolts for mounting to base Base table kits are NOT USE...

Page 50: ...IG This fixture is used for holding smal samples for a puncture test Good for Jelly beans gum drops etc Requires Rotary Base Table TA RT KIT TA BEC BACK EXTRUSION CELL The Back Extrusion Cell is used...

Page 51: ...ure Table Base TA BT KIT TA BLS BILAYER SHEAR TEST FIXTURE This fixture uses a guillotine blade to separate a bilayer tablet while measuring shear strength Requires Fixture Base Table TA BT KIT TA BPS...

Page 52: ...of 8mm 6mm 4mm 2mm and one blank Requires Fixture Base Table TA BT KIT TA DGF DUAL GRIP FIXTURE These are multipurpose general jigs for tensile type testing The fixtures utilize a universal fitting e...

Page 53: ...ires Fixture Base Table TA BT KIT TA KSC KRAMER SHEAR CELL The Kramer Shear Cell follows principles of the Allo Kramer Shear Press Test cell 53mm X 57mm X 56mm has clear Perspex front for viewing test...

Page 54: ...to evaluate noodle quality Requires Fixture Base Table TA BT KIT TA OC OTTAWA CELL The Ottawa cell follows principles of the Ottawa Test Measurement System OTMS Test cell 45mm X 45mm X 55mm has clear...

Page 55: ...ient of friction for packaging materials according to ASTM D1894 Requires Fixture Base Table TA BT KIT TA STF SPREAD TEST FIXTURE This fixture quantifies the force to spread a material on a surface Th...

Page 56: ...item generating an indication of sample toughness or fibrousness Consisting of both upper and lower jaws the compressive movement of the travelling beam imitates the human biting action Requires Fixtu...

Page 57: ...traceable to NIST standards TA CW 10KGC CALIBRATION WEIGHT SET 10kg WITH CASE CERTIFICATE Set of weights total mass 10kg to be used to check calibration of the 10kg CT3 Texture Analyzer Includes verif...

Page 58: ...TC 351 to one TC 450MX bath set to 10 C Second TC 450MX bath is set to 60 C providing rapid transfer between the thermal environments necessary for conditioning gelatin for Bloom testing Each bath has...

Page 59: ...won t move Ensure the locking knob is loose Ensure the fine adjust nut is loose Rotary Base table will not travel to the lowest position Loosen the fine adjust nut and rotate base table Locate the ta...

Page 60: ...in the CT3 labeled 0 9 All memory slots containing tests will appear in sequence as the SELECT SCROLL knob is rotated Memory slots can later be hidden by erasing a test using the Erase Test button whe...

Page 61: ...o change a parameter in a test that has been downloaded to the CT3 you can make the change and download the test to the same memory slot in the CT3 This will overwrite the initial program Target Hold...

Page 62: ...8 Stop Bits 1 Parity None Handshake None 2 3 4 5 6 7 8 9 1 No Connection Transmit Data TxD Receive Cable Sensing Cable Sensing Serial Ground No Connection No Connection No Connection Data RxD Pins 4...

Page 63: ...to copyright restrictions these articles cannot be emailed Please request your hardcopy of articles by calling our customer service department directly or by emailing marketing brookfieldengineering c...

Page 64: ...repair or service outside the United States consult AMETEK Brookfield or the dealer from whom you purchased the instrument For repair or service in the United Kingdom return to AMETEK GB Limited Brook...