P/N 98-0115 

3  

3.  Once the power source has been connected, check the rotation of the 

pump.  Turn the disconnect to the ON position.  Jog each pump by 
momentarily turning the pump power switch to the HAND position.  A 
second person may be needed to see which way the motor armature is 
turning just before it coasts to a stop.  If the rotation is backwards, switch 
any two of the three non-ground pump wires on the motor contactor inside 
the panel. 

4.  After rotation has been verified, turn the switches on the controller to 

HAND.  Allow water to flow to re-circulate through the loop and back in to 
the storage tank for a few minutes.  Water flow can be verified by 
observing the flow meter on the return header of the storage tank.  If this 
is a dual pump system, place pump #1 into HAND mode to ensure that 
there is adequate flow through the system at the holding tank flow meter.  
Once verified, repeat this for pump #2. 

5.   Place the system into auto mode to verify that the low level cut off switch 

operates correctly.  For a dual pump system, this will need to be done for 
each pump. 

6.  For the dual pump system only, the timer will need to be verified.  This is 

accomplished by setting the timer to its minimum value and ensuring that 
the system is alternating between the pumps.  See page 5 for details on 
adjusting the set-point. 

7.  The inlet and outlet valves are provided to allow for isolation of each pump 

if maintenance is needed.  During operation, leave all of the inlet and 
outlet valves open. 

8.  The rated flow for your distribution pump is 70 PSI.  When performing a 

start-up of your distribution pump that is connected to a central system 
storage tank, adjust the pressure relief valve on the storage tank header 
so that the pressure gage at the pump is no higher than 70 PSI. Refer to 
the manual that was provided with your storage tank system for proper 
adjustments.  Pump curves have been provided on page 4. 

Summary of Contents for GRUNDFOS CHI

Page 1: ...P N 98 0115 Rev A DISTRIBUTION PUMP SYSTEM OPERATION MAINTENANCE MANUAL GRUNDFOS CHI PUMPS Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414...

Page 2: ...P N 98 0115 Rev A...

Page 3: ...A TABLE OF CONTENTS THEORY OF OPERATION 1 INSTALLATION 2 START UP 2 PUMP GENERAL DATA 4 PUMP CURVES 5 PUMP TECHNICAL DATA 6 PUMP CONNECTIONS 8 ADJUSTING THE TIMER DUAL PUMPS ONLY 10 SPARE PARTS LISTIN...

Page 4: ...ailable as a single pump or a dual pump All distribution pumps are available in 115V and 220V single phase 208V 3 phase 230V 3 phase and 460V 3 phase The distribution pumps have a capability of runnin...

Page 5: ...AmeriWater Central Water System refer to the Plumbing and Instrumentation Diagram P ID for the best location and where connections are made 6 Follow all local plumbing and electrical codes 7 After gu...

Page 6: ...ing tank flow meter Once verified repeat this for pump 2 5 Place the system into auto mode to verify that the low level cut off switch operates correctly For a dual pump system this will need to be do...

Page 7: ...P N 98 0115 4 GRUNDFOS Pump...

Page 8: ...P N 98 0115 5...

Page 9: ...P N 98 0115 6...

Page 10: ...P N 98 0115 7...

Page 11: ...P N 98 0115 8 Pump Connections...

Page 12: ...P N 98 0115 9 Pump Connections...

Page 13: ...as shown below To adjust the timer simply insert a small screwdriver into the screw lower right hand face of the timer Rotating this will toggle between the time interval modes which are displayed on...

Page 14: ...0 460V 80 0135 Pump 1HP Single Phase 115 230V 041 0033 Check Valve Ball Spring Loaded 43530710 Stainless Steel Pressure Gauge 0 100psi 61670245 Contactor AB 9 AMP 3 Pole 120V Coil 61760226 Motor Conta...

Page 15: ...P N 98 0115 12 Single Distribution Single Phase Controller...

Page 16: ...P N 98 0115 13 Single Distribution 115 220V Single Phase Controller Schematic...

Page 17: ...P N 98 0115 14 Single Distribution Three Phase Controller...

Page 18: ...P N 98 0115 15 Single Distribution 208V 230V Three Phase Controller Schematic...

Page 19: ...P N 98 0115 16 Single Distribution 460V Three Phase Controller Schematic...

Page 20: ...P N 98 0115 17 Dual Distribution Single Phase Controller...

Page 21: ...P N 98 0115 18 Dual Distribution 220V Single Phase Controller Schematic...

Page 22: ...P N 98 0115 19 Dual Distribution Three Phase Controller...

Page 23: ...P N 98 0115 20 Dual Distribution 208V Three Phase Controller Schematic...

Page 24: ...P N 98 0115 21 Dual Distribution 230 Volt Three Phase Controller Schematic...

Page 25: ...P N 98 0115 22 Dual Distribution 460 Volt Three Phase Controller Schematic...

Page 26: ...P N 98 0115 23 Single Distribution Pump Assembly...

Page 27: ...P N 98 0115 24 Dual Distribution Pump Assembly...

Page 28: ...fornia to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may conta...

Reviews: