3.0  INSTALLATION 

CAUTION:

Local plumbing and electrical codes must be observed

.   

The following guidelines should be met at installation.  

1.  Customer is to provide properly sized wiring to the distribution pump control enclosure. 

2.  Place the pump system on firm, level floor and anchor to the floor to prevent movement 

from vibration or bumping. 

3.  Inlet piping and / or hoses from the storage tank to the pump system should be equal to 

or greater in diameter than the inlet piping on the pump system. 

4.  Outlet piping and / or hoses of the pump system should be equal to or greater in 

diameter than the outlet piping on the pump system. 

5.  Locate the pump control on a wall as close to the pump system as possible.  When 

installing a distribution pump along with an AmeriWater Central Water System, refer to 
the Plumbing and Instrumentation Diagram (P&ID) for the best location and where 
connections are made. 

6.  Follow all local plumbing and electrical codes. 

7.  After guidelines have been met, connect the distribution pump wiring to the motor 

contactor located in the control panel (refer to the control wiring diagram provided in 
this manual and with the distribution pump control).  Connect the three phase or single 
phase power source to the Main ON/OFF disconnect switch located inside the control 
panel. 

CAUTION:

For three phase systems, check the rotation of the pump.  Turn the main 
power disconnect to the on position and observe the rotation of the pump.  
When facing the motor end, correct rotation is in the clockwise rotation.  If 
the rotation is backwards, switch two pump wires on the motor contactor 
inside the panel.

4.0  START-UP 

1.  Open the inlet and outlet valves to the pump and allow the water in the storage tank to 

“flood” the inlet of the distribution pump.  If the storage tank does not have water in it, 
fill it to above the lowest float switch before attempting to use the pump.  

2.  To prime the pump, close the discharge valve.  Remove the vent plug.  For 2SV only, 

fully unscrew the pin located in the drain plug.  Open the suction valve until liquid flows 
out of the vent plug opening. 

NOTE: 

Place a loose rag over the open vent port to prevent large amounts of liquid from 

being sprayed on the pump and adjacent equipment.   

Summary of Contents for DISTRIBUTION PUMP SYSTEM

Page 1: ...SSV DISTRIBUTION PUMP SYSTEM OPERATION MAINTENANCE MANUAL Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414 P N 98 0096 REV A...

Page 2: ...0 INTRODUCTION 1 2 0 THEORY OF OPERATION 1 3 0 INSTALLATION 2 4 0 START UP 2 5 0 DAILY MONITORING 3 6 0 ADJUSTING THE TIMER 4 7 0 SPARE PARTS LIST 5 8 0 PUMP CURVES 6 9 0 SYSTEM DRAWINGS 8 10 0 TROUB...

Page 3: ...is process Running the distribution pump for an extended period without water will result with overheating and damage to the pump The distribution pumps are available as a single pump or a dual pump A...

Page 4: ...on pump wiring to the motor contactor located in the control panel refer to the control wiring diagram provided in this manual and with the distribution pump control Connect the three phase or single...

Page 5: ...that the low level cut off switch operates correctly For a dual pump system this will need to be done for each pump 8 For the dual pump system only the timer will need to be verified This is accompli...

Page 6: ...shown below To adjust the timer simply insert a small screwdriver into the screw on the lower right hand face of the timer Rotating this will toggle between the time interval modes which are displaye...

Page 7: ...3 Pump 3HP Three Phase 60GPM 80 SV04 Check Valve Ball Spring Loaded 041 0033 Stainless Steel Pressure Gauge 0 100psi 43530710 Contactor AB 9 AMP 3 Pole 120V Coil 61670245 Motor Contactor Overload 12 A...

Page 8: ...98 0096A 6 10 0 PUMP CURVES...

Page 9: ...98 0096A 7...

Page 10: ...98 0096A 8 9 0 SYSTEM DRAWINGS Single Distribution Single Phase Controller...

Page 11: ...98 0096A 9 Single Distribution Single Phase Controller Schematic...

Page 12: ...98 0096A 10 Single Distribution Three Phase Controller...

Page 13: ...98 0096A 11 Single Distribution Three Phase Controller Schematic...

Page 14: ...98 0096A 12 Dual Distribution Controller...

Page 15: ...98 0096A 13 Dual Distribution 220 Volt Single Phase Controller Schematic Dual Distribution 208 Volt Three Phase Controller Schematic...

Page 16: ...98 0096A 14...

Page 17: ...98 0096A 15 Dual Distribution 230 460 Volt 3 Phase Controller Schematic...

Page 18: ...98 0096A 16 Single Distribution Pump Assembly...

Page 19: ...98 0096A 17 Dual Distribution Pump Assembly...

Page 20: ...e at each station one valve at a time until water begins to escape When water begins to escape close the valve and proceed to the next station This will purge all of the air from the loop Verify that...

Page 21: ...rnia to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may contain...

Reviews: