CLEAN IN PLACE 

OPERATION & MAINTENANCE INSTRUCTIONS 

MODEL CIP1 

Manufactured With Pride 

In The USA

www.ameriwater.com  • 800-535-5585 

AmeriWater  • 3345 Stop 8 Rd  • Dayton, OH 45414

Summary of Contents for CIP1

Page 1: ...Part Number 98 0007 Revision E CLEAN IN PLACE OPERATION MAINTENANCE INSTRUCTIONS MODEL CIP1 Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414...

Page 2: ......

Page 3: ...TABLE OF CONTENTS OBJECTIVE 1 CHEMICALS REQUIRED 1 INSTALLATION 2 HIGH pH CLEANING 3 LOW pH CLEANING 5 FLUSH AND RETURN TO SERVICE 6 SPARE PARTS LIST 7...

Page 4: ...oulants from polyamide thin film composite membranes 1 lb 372 ml of AmeriClean B powder is required per membrane cleaning AmeriClean B effectively removes the following foulants Silt Microbiological C...

Page 5: ...E 1 5 Connect the RO Incoming Tap Water Hose to the male garden hose thread fitting on the CIP Pump Outlet FIGURE 2 6 Remove the carbon tank if applicable from the RO and install the provided jumper f...

Page 6: ...s dissolved before continuing WARNING Wear appropriate eye and skin protection when handling the membrane cleaning chemicals The cleaners are high pH and low pH chemicals that may cause severe chemica...

Page 7: ...direct it to a drain Continue running to drain until the CIP drum is empty some solution may need to be manually dumped out of the CIP drum WARNING Never allow AmeriClean A and AmeriClean B to mix Mix...

Page 8: ...hemicals and may cause severe chemical burns Read the MSDS for further information 4 Connect the CIP pump power cord to a 120 VAC receptacle GFI recommended 5 Place the Flush Valve in FLUSH then turn...

Page 9: ...ect To Drain hose and Incoming Tap Water hose from the CIP system 2 Run the RO Product Water Hose and the Reject Water To Drain Hose to a drain 3 Reconnect the carbon tank if applicable to the RO 4 In...