Escort Stair Lift Installation Manual
Maintenance
SHOCK
HAZARD
To prevent electrical shock or damage to the lift, disconnect the 120 VAC power when
cleaning the lift. Never apply cleaning liquids directly on the rail mounted charging stations
or electrical safety switches.
REQUIRED MAINTENANCE
The rail gear should be cleaned
once a year
or more frequently if exposed to contaminants such as pet hair,
excessive dust, etc. Wipe debris from the gear teeth. Apply a small amount of lubricant onto a clean cloth
and wipe across the gear teeth. Do not apply too much lubricant. Over lubrication will attract dirt and debris.
Ensure all rail, footrest and seat support fasteners are tight.
The seat post and thrust roller bearings should be lubricated
once a year
or sooner if used frequently.
TIP
The seat post and thrust roller bearing should be lubricated with a copper based
antisieze lubricant.
DO NOT
use any type of light weight penetrating oil (WD-40,
GUNK, Kroil, Liquid Wrench etc.)
TIP
Gear rack should be lubricated with a multi-purpose calcium grease.
DO NOT USE
any type of light weight penetrating oil (WD-40, GUNK, Kroil,
Liquid Wrench etc.)
TIP
The lift and aluminum rail can be cleaned with any commercial window cleaner.
DO NOT USE
abrasive cleaners.